v
Do
not
overtighten
the
cable
straps
or
bend
the
cables
to
a
radius
of
less
than
38
mm
(1.5
in.).
v
Do
not
put
excess
weight
on
the
cable
at
the
connection
point.
Be
sure
that
the
cable
is
well
supported.
Installing
SFP
modules
The
FAStT100
host
ports
require
SFP
modules.
SFP
modules
are
used
to
convert
electrical
signals
to
optical
signals
that
are
required
for
fibre
channel
transmission
to
and
from
RAID
controllers.
The
FAStT100
supports
two
types
of
SFP
modules:
one
with
a
plastic
latch
and
one
with
a
wire
latch.
After
you
install
the
SFP
modules,
you
use
fiber-optic
cables
to
connect
the
FAStT100
to
other
fibre
channel
devices.
Before
you
install
SFP
modules
and
fiber-optic
cables,
read
the
following
information:
v
Do
not
mix
long-wave
SFPs
and
short-wave
SFPs
on
a
single
storage
server.
Use
either
long-wave
SFPs
or
short-wave
SFPs.
You
can
use
the
Storage
Manager
client
to
view
the
Storage
Subsystem
Profile
in
order
to
verify
that
you
are
not
mixing
long-wave
and
short-wave
SFPs.
v
The
SFP
module
housing
has
an
integral
guide
key
designed
to
prevent
you
from
inserting
the
SFP
module
improperly.
v
Use
minimal
pressure
when
you
insert
the
SFP
module
into
a
port.
Forcing
the
SFP
module
into
a
port
could
cause
damage
to
the
SFP
module
or
the
port.
v
You
can
insert
or
remove
the
SFP
module
while
the
port
is
powered
on.
v
The
operational
loop
performance
is
not
affected
when
you
install
or
remove
an
SFP
module.
v
You
must
insert
the
SFP
module
into
a
port
before
you
connect
the
fiber-optic
cable.
v
You
must
remove
the
fiber-optic
cable
from
the
SFP
module
before
you
remove
the
SFP
module
from
the
port.
See
for
more
information.
To
install
an
SFP
module,
complete
the
following
steps.
Statement
3:
CAUTION:
When
laser
products
(such
as
CD-ROMs,
DVD
drives,
fiber-optic
devices,
or
transmitters)
are
installed,
note
the
following:
v
Do
not
remove
the
covers.
Removing
the
covers
of
the
laser
product
could
result
in
exposure
to
hazardous
laser
radiation.
There
are
no
serviceable
parts
inside
the
device.
v
Use
of
controls
or
adjustments
or
performance
of
procedures
other
than
those
specified
herein
might
result
in
hazardous
radiation
exposure.
40
IBM
TotalStorage
FAStT100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......