Each
drive
enclosure
in
a
FAStT
storage
subsystem
drive
loop
must
have
a
unique
drive
enclosure
ID.
FAStT
controllers
use
a
combination
of
the
enclosure
ID
and
the
number
of
the
physical
slot
that
a
fibre
channel
hard
drive
occupies
to
create
a
unique
fibre
channel
loop
address
or
arbitrated
loop
physical
address
(AL_PA)
for
each
drive
in
a
fibre
channel
drive
loop.
The
enclosure
ID
consists
of
two
digits,
a
tens
digit
(x10)
and
ones
digit
(x1).
Attention:
When
connecting
the
FAStT100
to
EXP100
drive
enclosures,
DO
NOT
use
the
tens
digit
(x10)
setting.
Use
only
the
ones
digit
(x1)
setting
to
set
unique
server
IDs
or
enclosure
IDs.
Give
each
drive
expansion
enclosure
in
a
redundant
drive
loop
a
unique
ones
digit
(x1)
ID.
This
setting
will
enforce
hard
AL_PAs
(unchangeable
between
fibre
channel
Loop
Initializations
[LIPs])
for
the
drives
and
facilitate
drive
loop
problem
troubleshooting
in
the
event
of
an
error.
If
the
ones
digits
are
not
unique,
two
or
more
devices
will
have
the
same
hard
AL_PA.
In
such
a
case,
the
controller
will
use
soft
AL_PAs
for
the
devices
that
have
identical
hard
AL_PAs.
The
problem
with
soft
addressing
is
that
addresses
may
change
between
LIPs.
This
possibility
increases
the
difficulty
of
troubleshooting
drive
loop
problems,
since
one
cannot
easily
ascertain
whether
the
same
device
with
a
different
address
or
different
device
may
be
causing
a
problem.
Note:
The
FAStT100
is
shipped
with
00
as
the
default
server
ID
setting.
If
you
connect
the
storage
server
to
a
FAStT
EXP100,
you
must
set
the
EXP100
enclosure
ID
setting
to
a
value
other
than
00.
Each
server
unit
should
have
a
unique
ID
if
it
is
going
to
be
connected
to
other
drive
expansion
units
through
the
drive
loop
ports.
The
Server
ID
setting
is
only
valid
for
the
drive
Server ID Switch
f10ug062
Figure
21.
Setting
the
Server
ID
30
IBM
TotalStorage
FAStT100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......
Page 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...