
Table
15.
Symptom-to-FRU
index
(continued)
Problem
indicator
Component
Possible
cause
Possible
solutions
The
Storage
Manager
client
Enterprise
Management
window
sees
each
storage
server
controller
as
an
independent
storage
subsystem
or
a
partially
managed
device.
Controller
No
drives
are
present
in
the
storage
server.
Ensure
that
at
least
one
drive
is
present
in
the
storage
server
so
that
it
can
be
configured
properly.
One
controller
was
replaced
incorrectly.
The
controller
firmware
versions
probably
failed
to
synchronize
correctly.
To
recover,
perform
the
following
steps:
1.
Remove
and
reinsert
the
controller
blade.
2.
Wait
5
minutes.
3.
Delete
the
controller
entry
with
the
incorrect
firmware
version
from
the
FAStT
Storage
Manager
Enterprise
Management
window.
4.
Add
the
controller
back
to
the
FAStT
Storage
Manager
Enterprise
Management
window
using
the
Add
Device
menu
option
in
the
Enterprise
Management
window.
5.
If
the
Storage
Manager
client
Enterprise
Management
window
still
shows
each
storage
server
controller
as
an
independent
storage
subsystem
or
a
partially
managed
device,
repeat
this
procedure.
If
the
problem
still
persists,
contact
IBM
support.
Note:
If
you
cannot
find
the
problem
in
the
Symptom-to-FRU
index,
test
the
entire
system.
Parts
listing
and
the
following
table
provide
a
parts
listing
for
the
FAStT100
(P/N
24P8966).
Chapter
6.
Hardware
maintenance
99
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......
Page 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...