Table
15.
Symptom-to-FRU
index
Problem
indicator
Component
Possible
cause
Possible
solutions
Amber
LED
on
Drive
CRU
Drive
failure
Replace
the
drive
that
has
failed.
Fan
CRU
Fan
failure
Replace
the
fan
that
has
failed.
RAID
controller
Fault
LED
RAID
controller
failure
If
the
RAID
controller
Fault
LED
is
on,
replace
the
RAID
controller.
If
the
RAID
controller
has
been
placed
offline
by
the
user,
use
storage
management
software
to
place
it
online.
If
the
controller
failed,
replace
the
RAID
controller.
Expansion
or
host
port
bypass
LED
SFP
port
empty
No
corrective
action
is
needed
if
this
is
a
stand-alone
storage
server
with
no
expansion
units
attached,
and
if
the
system
is
properly
configured.
Otherwise,
check
to
make
sure
that
the
drive
expansion
unit
is
powered
on
and
the
FC
cables
are
attached
properly.
Fibre-channel
cable
is
not
attached
to
the
expansion
unit
Connect
the
fibre-channel
cable
to
the
enclosure
port;
check
other
connections.
No
incoming
signal
detected
Reattach
the
SFPs
and
fibre-channel
cables.
Replace
input
and
output
SFPs
or
cables
as
necessary.
Front
panel
General
system
error
Indicates
that
a
Fault
LED
somewhere
on
the
storage
server
has
turned
on.
(Check
for
amber
LEDs
on
CRUs.).
Use
Storage
Manager
software
to
diagnose
server
problems.
Amber
LED
is
off
and
green
LED
off
Power-supply
CRU
Power
switch
is
turned
off
or
ac
power
failure
Turn
on
all
power-supply
power
switches.
Amber
and
green
LEDs
on
Power-supply
CRU
Power
supply
failure
Replace
the
failed
power-supply
CRU.
96
IBM
TotalStorage
FAStT100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......
Page 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...