Upgrading
the
firmware
Attention:
The
firmware
upgrade
procedure
requires
the
out-of-band
(Ethernet)
management
connections
to
both
controllers
in
the
connected
DS4000
storage
server.
You
can
define
the
controller
TCP/IP
addresses
in
the
following
three
ways:
v
By
default
(to
192.168.128.101
and
192.168.128.102
for
Controllers
A
and
B
respectively)
v
By
a
DHCP/BootP
server
v
By
static
definition.
Existing
DS4000
controllers
have
stored
TCP/IP
addresses
that
can
be
used
for
static
definition.
Use
the
following
procedures
to
upgrade
a
DS4000
Storage
Server
manually
to
controller
firmware
version
6.10.xx.xx.
1.
Power
off
the
DS4000
storage
server
configuration
and
the
DS4000
EXP710s,
if
applicable.
2.
With
the
DS4000
storage
server
and
the
DS4000
EXP710s
powered
off,
establish
all
fibre-channel
cabling
connections
and
management
Ethernet
connections.
Refer
to
Note:
Do
not
power
on
any
units
yet.
3.
Install
Storage
Manager
9.1
in
the
management
station.
Refer
to
the
IBM
TotalStorage
DS4000
Storage
Manager
Version
9
Installation
and
Support
Guide
for
your
operating
system
for
more
information
on
this
upgrade
procedure
and
any
system
requirements.
Attention:
The
management
station
must
have
an
Ethernet
connection
to
the
same
network
as
the
two
controllers
in
the
DS4000
storage
server.
4.
Remove
Controller
A
from
the
DS4000
storage
server.
Important:
If
you
do
not
remove
Controller
A
from
the
DS4000
storage
server,
the
new
firmware
may
not
be
downloaded
correctly
on
both
controllers
and
the
controllers
will
not
recognize
the
disk
drives.
Refer
to
the
appropriate
DS4000
storage
server
installation
and
user’s
guide
for
the
location
and
the
instructions
on
how
to
remove
the
controller
in
a
DS4000
storage
server.
Note:
For
the
DS4400
and
DS4500,
Controller
A
is
the
top
controller
when
looking
at
the
front
of
the
unit.
For
the
DS4300,
Controller
A
is
the
left
controller
when
looking
at
the
back
of
the
unit.
Observe
handling
static-sensitive
device
precautions
described
in
when
removing
the
DS4000
storage
server
controller.
5.
Power
on
the
DS4000
storage
server
only.
Both
power
supplies
must
be
powered
on
for
maximum
protection
against
power
loss.
6.
Open
a
DS4000
Storage
Manger
Client
Enterprise
Management
window
to
manage
the
DS4000
storage
server
for
which
you
are
upgrading
the
firmware.
Refer
to
the
IBM
TotalStorage
DS4000
Storage
Manager
Version
9
Installation
and
Support
Guide
for
the
host
operating
system
of
your
DS4000
management
station
for
more
information.
7.
Add
the
TCP/IP
address
for
Controller
B
to
the
Enterprise
Management
window
of
the
DS4000
Storage
Manager
9
client
program.
a.
In
the
Enterprise
Management
Window,
click
Edit
→
Add
Device
.
94
IBM
TotalStorage
DS4000
EXP700
and
EXP710
Storage
Expansion
Enclosures:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for TotalStorage FAStT EXP700
Page 2: ......
Page 157: ......
Page 158: ...Part Number 25R0398 Printed in USA gc26 7735 00 1P P N 25R0398...