
Table
4.
Features
at
a
glance
General
v
Modular
components:
–
High-capacity
Fibre
Channel
disk
drives
–
RAID
controllers
–
Power
supplies
–
Cooling
fans
v
Technology:
–
Support
for
disk
arrays
–
Support
for
clustering
–
Fibre-channel
host
interface
–
Redundant
data
storage,
cooling
system,
power
system,
and
RAID
controllers
(Model
60U/60X
only)
–
Hot-swap
technology
for
power
supplies
and
RAID
controllers
(Model
60U/60X
only)
–
Hot-swap
technology
for
fibre-channel
hard
drives
and
fans
(all
models).
Attention:
You
will
lose
data
if
you
attempt
to
hot
swap
the
controller
and
power
supply
components
in
a
DS4300
single-controller
storage
subsystem
(Model
6LU/6LX).
v
User
interface:
–
Built-in
power,
activity,
and
fault
light
emitting
diodes
(LEDs)
–
Identification
labeling
on
customer
replaceable
units
(CRUs),
rear
LEDs,
switches,
and
connectors
–
Easy-to-replace
drives,
power
supplies,
RAID
controllers,
and
fans
Disk
drive
storage
2-Gbps
Fibre
Channel
enclosure
Maximum
drives
per
storage
subsystem:
14
Attached
storage
expansion
enclosures
v
For
Model
60U/60X,
attachment
of
DS4000
EXP
storage
expansion
enclosures
requires
one
or
more
EXP
storage
expansion
enclosure
Attachment
option
(or
feature)
upgrades
for
the
DS4300
v
2-Gbps
connection
only
RAID
controllers
v
Technology
and
interfaces:
–
Fibre
Channel:
40-pin
fibre-channel
disk
drives
–
Fibre
Channel
interface:
-
For
Model
60U/60X,
six
small
form-factor
pluggable
(SFP)
modules
for
incoming
and
outgoing
fibre-channel
cables
(three
SFPs
on
each
RAID
controller).
-
For
Model
6LU/6LX,
two
SFP
modules
for
incoming
fibre-channel
cables
(two
SFPs
on
the
RAID
controller).
–
Two
auto-negotiate
1
Gbps/2
Gbps
fibre-channel
host-side
connections
per
controller
Clustering
support
Clustering
is
a
means
of
sharing
array
groups
among
controllers
to
provide
redundancy
of
controllers
and
servers.
This
redundancy
is
important
if
a
hardware
component
fails.
If
a
hardware
component
failure
occurs
in
a
cluster,
another
server
takes
ownership
of
the
array
group.
Clustering
requires
software
specific
to
your
operating
system.
For
more
information
about
clustering,
go
to
the
following
Web
sites:
www.pc.ibm.com/us/compat/nos/matrix.shtml
www.ibm.com/servers/storage/disk/ds4000/interop-matrix.html
Inventory
checklist
After
you
unpack
the
storage
subsystem,
verify
that
you
have
the
following
items:
Hardware
IBM
DS4300
storage
subsystem
comes
with
the
following
components:
v
RAID
controllers:
–
2
controllers
on
Model
60U/60X
–
1
controller
on
Model
6LU/6LX
v
Power
supplies:
–
2
power
supplies
on
Model
60U/60X
–
1
power
supply
on
Model
6LU/6LX
v
Power
cords:
–
Two
power
cords
on
Model
60U/60X
8
IBM
TotalStorage
DS4300
Fibre
Channel
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for TotalStorage DS4300 Turbo
Page 2: ......
Page 219: ......
Page 220: ...Part Number 42D3300 Printed in USA GC26 7722 02 1P P N 42D3300...