Temperature checkout
Proper cooling of the system is important for proper operation and system reliability.
For a typical appliance, you should make sure that:
v
Each of the drive bays has either a drive or a filler panel installed.
v
Each of the power supply bays has either a power supply or a filler panel
installed.
v
The top cover is in place during normal operation.
v
There is at least 50 mm (2 in.) of ventilated space at the sides of the appliance
and 100 mm (4 in.) at the rear of the appliance.
v
The top cover is removed for no longer than 30 minutes while the appliance is
operating.
v
The processor housing cover covering the processor and memory area is
removed for no longer that 10 minutes while the appliance is operating.
v
A removed hot-swap drive is replaced within 2 minutes of removal.
v
Cables for optional adapters are routed according to the instructions provided
with the adapters (ensure that cables are not restricting air flow).
v
The fans are operating correctly and the air flow is good.
v
A failed fan is replaced within 48 hours.
In addition, ensure that the environmental specifications for the system are met.
See “Appendix C. Specifications” on page 117.
For more information on specific temperature error messages, see “Temperature
error messages” on page 37.
Troubleshooting the IDE drive
This section describes symptoms and diagnostics. See “Installing a non-hot-swap
drive or CD-ROM” on page 60 for information on replacing an IDE drive.
Symptoms
The following symptoms may indicate a problem with your IDE drive:
v
You can no longer ping the appliance from the management workstation.
v
The system appears to be hung.
Running IDE diagnostics
Follow these steps to run IDE diagnostics:
1. Attach a monitor and keyboard to the appliance.
2. Start the appliance.
3. Press
F2
for System Diagnostics. Wait until it boots. A panel saying
4. If the non-hot-swap (IDE) drive fails, you will need to replace it (see “Installing a
non-hot-swap drive or CD-ROM” on page 60).
5. Download a new system image from www.ibm.com/storage/support/nas and
install the new image on the network’s FTP server.
6. Run the Recovery CD (see ).
12
Models 200 and 225 Service Guide
Summary of Contents for totalstorage 200
Page 1: ...IBM TotalStorage Network Attached Storage Models 200 and 225 Service Guide ...
Page 2: ......
Page 3: ...IBM TotalStorage Network Attached Storage Models 200 and 225 Service Guide ...
Page 8: ...vi Models 200 and 225 Service Guide ...
Page 12: ...x Models 200 and 225 Service Guide ...
Page 14: ...xii Models 200 and 225 Service Guide ...
Page 16: ...xiv Models 200 and 225 Service Guide ...
Page 30: ...14 Models 200 and 225 Service Guide ...
Page 58: ...42 Models 200 and 225 Service Guide ...
Page 108: ...92 Models 200 and 225 Service Guide ...
Page 120: ...104 Models 200 and 225 Service Guide ...
Page 130: ...114 Models 200 and 225 Service Guide ...
Page 134: ...118 Models 200 and 225 Service Guide ...
Page 149: ...Appendix D Notices 133 ...
Page 150: ...134 Models 200 and 225 Service Guide ...
Page 151: ...Appendix D Notices 135 ...
Page 152: ...136 Models 200 and 225 Service Guide ...
Page 153: ...Appendix D Notices 137 ...
Page 154: ...138 Models 200 and 225 Service Guide ...
Page 167: ...Appendix D Notices 151 ...
Page 179: ......