b.
Place the battery into its socket, and press the battery press the battery
toward the housing until it clicks into place. Make sure that the battery clip
holds the battery securely.
3.
Install the cover (see “Replacing the server top cover” on page 265).
4.
Slide the server into the rack.
5.
Reconnect the external cables; then, reconnect the power cords and turn on the
peripheral devices and the server.
Note:
You must wait approximately 1 to 3 minutes after you connect the server
to a power source before the power-control button becomes active.
6.
Start the Setup utility and reset the configuration.
v
Set the system date and time.
v
Set the power-on password.
v
Reconfigure the server.
See “Using the Setup utility” on page 402 for details.
Removing a PCI riser-card assembly
To remove a PCI riser-card assembly, complete the following steps:
1.
Read the safety information and installation guidelines, see “Safety” on page vii
and the “Installation guidelines” on page 261.
2.
Turn off the server (see “Turning off the server” on page 17) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3.
Remove the top cover (see “Removing the server top cover” on page 264).
4.
If an adapter is installed in the PCI riser-card assembly, disconnect any cables
that are connected to the adapter.
5.
Grasp the front and rear of the PCI riser-card assembly at the blue touch-points
and lift it out of the PCI riser-card slot on the system board.
336
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...