Note:
Some
operating
systems
have
size
limitations
for
logical
drives.
Before
you
save
the
configuration,
make
sure
that
the
size
of
the
logical
drive
is
appropriate
for
your
operating
system.
5.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
6.
Exit
from
ServeRAID
Manager
and
remove
the
CD
from
the
CD
or
DVD
drive.
7.
Restart
the
server.
Using
custom
configuration
:
To
use
custom
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller.
2.
Click
Custom
configuration
.
3.
Click
Next
.
4.
In
the
“Create
arrays”
window,
from
the
list
of
ready
drives,
select
the
two
drives
that
you
want
to
move
into
the
array.
5.
Click
the
(Add
selected
drives)
icon
to
add
the
drives
to
the
array.
6.
If
you
want
to
configure
a
hot-spare
drive,
complete
the
following
steps:
a.
Click
the
Spares
tab.
b.
Select
the
physical
drive
that
you
want
to
designate
as
the
hot-spare
drive,
and
click
the
icon
to
add
the
drive.
7.
Click
Next
.
8.
In
the
“Configuration
summary”
window,
review
the
information.
To
change
the
configuration,
click
Back
.
9.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
10.
Exit
from
ServeRAID
Manager,
and
remove
the
CD
from
the
CD
or
DVD
drive.
11.
Restart
the
server.
Viewing
the
configuration
You
can
use
ServeRAID
Manager
to
view
information
about
RAID
controllers
and
the
RAID
subsystem
(such
as
arrays,
logical
drives,
hot-spare
drives,
and
physical
drives).
When
you
click
an
object
in
the
ServeRAID
Manager
tree,
information
about
that
object
appears
in
the
right
pane.
To
display
a
list
of
available
actions
for
an
object,
click
the
object
and
click
Actions
.
Using
the
Boot
Menu
program
The
Boot
Menu
program
is
a
built-in,
menu-driven
configuration
program
that
you
can
use
to
temporarily
redefine
the
first
startup
device
without
changing
settings
in
the
Configuration/Setup
Utility
program.
To
use
the
Boot
Menu
program,
complete
the
following
steps:
1.
Turn
off
the
server.
2.
Restart
the
server.
3.
Press
F12.
4.
Select
the
startup
device.
The
next
time
the
server
is
started,
it
returns
to
the
startup
sequence
that
is
set
in
the
Configuration/Setup
Utility
program.
172
System
x3400
Types
7973,
7974,
7975,
and
7976:
Problem
Determination
and
Service
Guide
Summary of Contents for System x3400 Type 7973
Page 1: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 8: ...vi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 18: ...xvi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 34: ...16 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 104: ...86 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 112: ...94 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 182: ...164 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 192: ...174 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 200: ...182 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Page 209: ......
Page 210: ...Part Number 31R2197 Printed in USA 1P P N 31R2197...