v
If the test fails, replace the fiber cable.
v
If the test is successful, go to step 6.
6.
Check the Fibre Channel cable connection at the server.
7.
Using a device driver utility such as
ntutil
or
tapeutil
, verify that the drive is
properly configured and available at the server.
8.
If the problem persists, the fault may be with the server's hardware or software.
Refer to your server's service manual.
9.
When the problem is corrected (or determined to be a server problem), restore
all of the fiber cables to their correct position.
Fixing a Consistent Error with Multiple Drives on a Fibre
Channel Loop
Use the following procedure to determine if all of the drives on the Fibre Channel
have the problem:
1.
Use a device driver utility (such as
ntutil
or
tapeutil
) to verify that the drive is
available and properly configured at the server.
2.
Determine the type of Fibre Channel topology that you are using.
3.
Using this guide or the service guides of associated switch, hub, or fiber
products, try to isolate which part of the Fibre Channel Storage Area Network
(SAN) is experiencing problems.
4.
Perform one of the following:
v
If the problem exists on a small number of drives, go to “Fixing a Consistent
Error with a Single Drive on a Fibre Channel Loop” on page D-55.
v
If the problem exists with a large number of drives, perform the following
steps:
a.
Disconnect all except one failing drive on the Fibre Channel.
b.
Run the Fibre Channel wrap test to determine if a failure occurs on that
drive (see Function Code 6 in “Function Code 6: Run Host Interface Wrap
Test” on page D-32). If it does, perform the procedure in “Fixing a
Consistent Error with a Single Drive on a Fibre Channel Loop” on page
D-55.
c.
Continue to connect one drive at a time to the Fibre Channel loop.
5.
When the problem is corrected, restore all of the Fibre Channel cables to their
correct position.
Fixing a Consistent Error in a Point-to-Point Topology
1.
Ensure that the tape drive is powered ON.
2.
Verify that the tape drive's serial number is the same as the drive serial number
that the server program is using.
3.
Ensure that the drive is connected to the host or switch. The drive must be able
to detect light and communicate with the server.
4.
Run the Fibre Channel wrap test at the drive's Fibre Channel connector (see
Function Code 6 in “Function Code 6: Run Host Interface Wrap Test” on page
D-32).
v
If the test fails, replace the tape drive.
v
If the test is successful, go to step 5.
5.
Run the Fibre Channel wrap test at the end of the fiber cable (see Function
Code 6 in “Function Code 6: Run Host Interface Wrap Test” on page D-32).
v
If the test fails, replace the fiber cable.
D-56
TS3310 Tape Library Maintenance Information
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...