T061: Tape Alert 55 - Loading Fail
Description
GUI Description: The tape drive encountered a problem while loading a tape
cartridge.
Explanation: When loading a tape into drive, a hardware malfunction can
prevent the tape from being loaded in the drive, or the tape may actually get
stuck in the drive.
Detection Scenarios
After loading a drive, the drive generates a Tape Alert 55, which is noticed
by the library.
Root Causes
1.
A drive hardware error that prevents the tape from being loaded.
2.
A damaged tape that cannot be loaded into the drive.
Possible FRU Replacements
v
Drive sled
Resolution
1.
Perform “DR078: Resolve Tape Load/Unload Failure” on page 6-83.
2.
Use the "Details" option in the RAS ticket to identify which tape drive
reported the RAS ticket. Check for lock block condition. If possible, check
the front of the tape drive for error indications. Clear the RAS ticket.
3.
Open the main door and inspect the tape drive or path for obstruction.
4.
Isolate the media used during the load operation and verify it is not
damaged.
5.
Finally, pull the drive sled from the sled bay and reseat it in another sled
bay and retry the load operation. Additionally if using 400G library
firmware or later, run the IVT - Drive test from the Library Tests option
accessed through the Operator Panel.
Note:
IVT is optimized for library firmware versions 520G and above
and libraries built after July 1, 2008 (serial numbers with last four digits
8609 and above).
v
If your library was built on or before July 1, 2008, and you are running
firmware version 520G or above, you will not be able to run the IVT
test, even though the selection is available.
v
If your library was built on or before July 1, 2008, and you are running
firmware version 500G or below, you can run the test, but it is not
recommended because it may produce erroneous results.
T062: Module Configuration Problem
Description
GUI Description: The library cannot determine its module configuration due
to module-to-module cable connection or a module termination failure.
Explanation: At boot time or run time the library physical frame
configuration is not valid. The configuration is determined via address bits
and module count bits that are routed through the module to module cabling
and termination.
Chapter 6. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx)
6-27
Summary of Contents for System Storage TS3310
Page 2: ......
Page 6: ...iv TS3310 Tape Library Maintenance Information...
Page 8: ...vi TS3310 Tape Library Maintenance Information...
Page 18: ...xvi TS3310 Tape Library Maintenance Information...
Page 20: ...xviii TS3310 Tape Library Maintenance Information...
Page 22: ...xx TS3310 Tape Library Maintenance Information...
Page 28: ...1 6 TS3310 Tape Library Maintenance Information...
Page 76: ...3 14 TS3310 Tape Library Maintenance Information...
Page 92: ...4 16 TS3310 Tape Library Maintenance Information...
Page 196: ...6 94 TS3310 Tape Library Maintenance Information...
Page 242: ...7 46 TS3310 Tape Library Maintenance Information...
Page 378: ...8 136 TS3310 Tape Library Maintenance Information...
Page 382: ...9 4 TS3310 Tape Library Maintenance Information...
Page 390: ...10 8 TS3310 Tape Library Maintenance Information...
Page 396: ...A 6 TS3310 Tape Library Maintenance Information...
Page 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Page 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Page 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Page 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Page 421: ...a66mi036 Appendix C Library Diagrams C 13...
Page 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Page 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Page 484: ...D 60 TS3310 Tape Library Maintenance Information...
Page 494: ...E 10 TS3310 Tape Library Maintenance Information...
Page 498: ...F 4 TS3310 Tape Library Maintenance Information...
Page 504: ...G 6 TS3310 Tape Library Maintenance Information...
Page 520: ...H 16 TS3310 Tape Library Maintenance Information...
Page 526: ...X 6 TS3310 Tape Library Maintenance Information...
Page 529: ......
Page 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...