
v
If you are making Fibre Channel connections to N series mezzanine card, connect Fibre Channel cables
from the Fibre Channel ports (1a and 1b) to your storage expansion unit loop or Fibre Channel switch.
Make sure that SFPs are installed and firmly seated in the Fibre Channel ports (1a and 1b) of the
controller node and the In port of the first storage expansion unit in the loop before attaching a Fibre
Channel cable.
Note:
When you order an N3220 storage system without external storage expansion units, two QSFP SAS
cables and an ACP cable are required to enable the multipath high availability configuration. These cables
can be ordered as FC9563. If you order the storage system with external storage expansion units, the
cables come with storage expansion units.
Important: If you are connecting to EXN1000 or EXN4000 storage expansion units:
v
When using the optional 8 GB FC Mezzanine (FC2030) adapter Fibre Channel ports to connect to
EXN1000 or EXN4000 storage expansion units, the onboard ports must be set to initiator mode. For
more information, see the
IBM System Storage N3150, N3220, and N3240 Hardware and Service Guide
.
v
SFPs
must
be used when connecting fiber cables.
Notes:
1.
For SAN systems with quad-port host bus adapters (HBAs), see the
Multipath and Dual-Path Cabling
Information
document on the IBM N series support website:
www.ibm.com/storage/support/nseries/
2.
For required port usage and specifications for optional Mezzanine adapters supported by your N3220
system, refer to the
IBM System Storage N Series Introduction and Planning Guide
.
Installing the power cables
Use these instructions to install the power cables for the N3220 filer.
1.
Make sure all power supply switches on the N3220 filer and any attached expansion units are in the
Off position.
2.
For all storage systems that are being installed, connect the power cords to all power supply unit
(PSU) power receptacles using power cord retainer clips, making sure to slide the clip all the way
forward on the plug.
3.
Connect the power cords to the power sources, making sure that the two power supplies are
connected to separate AC sources. This ensures redundant power.
Attention:
Do not power on the system at this time.
Note:
The N3220 storage system has no requirement or provision for grounding.
For proper grounding of expansion units, see the
Installation and Setup Instructions
for the expansion
unit.
Setting up and booting the system in Data ONTAP 7-Mode
Use these instructions to set up and boot the N3220 filer.
1.
Make sure the Configuration worksheet from the
Data ONTAP Software Setup Guide for 7-Mode
is
completed and available for use.
Note:
IBM recommends that you print a copy of this worksheet from the
Data ONTAP Software Setup
Guide for 7-Mode
.
2.
Check that your system is properly set up. Make sure that the expansion unit IDs and speed
switches are properly set, and that the cabling is correct for your configuration.
3.
Start a console session for each controller module.
10
Summary of Contents for System Storage N3220
Page 4: ...iv...
Page 20: ...12...
Page 23: ......
Page 24: ...Part Number 00GM241 Printed in USA GA32 2202 02 1P P N 00GM241...