Syntax
stop cacheMemory controller [(a | b)] diagnostic
Parameters
Parameter
Description
controller
The controller that has the cache memory on which you are
running the diagnostic tests. Valid controller identifiers are
a
or
b
, where
a
is the controller in slot A, and
b
is the
controller in slot B. Enclose the controller identifier in square
brackets ([ ]). If you do not specify a controller, the storage
management software returns a syntax error.
Stop Storage Subsystem Configuration Database Diagnostic
This command stops the diagnostic test to validate the configuration database in the controller firmware
that was started by the
start storageSubsystem configDbDiagnostic
command.
Syntax
stop storageSubsystem configDbDiagnostic
Parameters
None.
Notes
The controller firmware returns a confirmation that the diagnostic test was cancelled.
In addition, you can start the database configuration diagnostic test through the storage management
software GUI; however, you cannot stop the database configuration diagnostic test through the storage
management software GUI. If you want to stop a running diagnostic test, you must use the
stopstorageSubsystem configDbDiagnostic
command.
If you try to use the
stop storageSubsystem configDbDiagnostic
command after validation of the storage
subsystem configuration has finished, you do not receive any message that the validation has finished.
This behavior is expected.
Stop Consistency Group Enhanced FlashCopy Rollback
This command stops a rollback operation to the member base logical drives in an Enhanced FlashCopy
consistency group that was initiated by the
start rollback cgEnhancedFlashCopy
command.
Note:
Canceling a consistency group Enhanced FlashCopy rollback operation leaves the base logical drive
in an indeterminate state with potentially invalid or inconsistent data. The related consistency group
Enhanced FlashCopy logical drive becomes disabled and unusable.
Syntax
stop cgEnhancedFlashCopyImage["consistencyGroupName"]| rollback
[memberLogicalDriveSet ["memberLogicalDriveName1 ... memberLogicalDriveNamen"]]
Chapter 3. Script Commands
3-307
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...