Syntax
start cgEnhancedFlashCopyImage ["consistencyGroupName"] rollback
[memberLogicalDriveSet ["memberLogicalDriveName1 ... memberLogicalDriveNamen"]]
Parameters
Parameter
Description
consistencyGroupName
The name of the consistency group for which you want
to start a rollback operation. Enclose the name of the
consistency group in double quotation marks (" ") inside
square brackets ([ ]). When the
memberLogicalDriveSet
parameter is not used, the rollback process applies to all
member logical drives of the consistency group.
memberLogicalDriveSet
The name of one or more member base logical drives in
a consistency group that you want to rollback. Enclose
each member base logical drive name in double
quotation marks (" ") inside parenthesizes (( )).
You can enter more than one member logical drive name.
Enclose all of the member logical drive names in one set
of double quotation marks (" ") inside parenthesizes (( )).
Separate each member logical drive name with a white
space.
Notes
To start a roll back operation for an entire consistency group that has the name
congroup1
, you would use
this command:
start cgEnhancedFlashCopyImage ["congroup1"] rollback;
To start a roll back operation for base logical drive members
memVol1, memVol2
, and
memVol3
in a
consistency group that has the name
congroup2
, you would use this command:
start cgEnhancedFlashCopyImage ["congroup2"] rollback memberLogicalDriveset=("memVol1 memVol2 memVol3");
Start Controller Diagnostic
This command runs diagnostic tests to evaluate the functionality of the controller card. Before you run
these tests, you must make these changes to the controller on which you want to run diagnostics:
v
Place the controller into Service Mode (use the
set controller [(a | b)]availability=serviceMode
command).
v
Attach the management client directly to the controller through the management Ethernet port.
Note:
In a dual controller configuration, you must run these diagnostic tests through the controller that
you want to evaluate. You cannot run these diagnostic tests through the partner controller.
Syntax
start controller [(a | b)] diagnostic diagnosticType=(basic | extended)
[extendedTestID=(SRAM | FIFO | dataCopy| RAID5Parity | RAID6Parity)]
Chapter 3. Script Commands
3-289
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...