![IBM Storwize V7000 Problem Determination Manual Download Page 45](http://html.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_problem-determination-manual_4062780045.webp)
of the Easy Setup Wizard and restart Easy Setup Wizard again. You have to key in
all fields for each step again. Once all steps are completed the system runs the
configuration and restarts.
GUI access issues
This topic provides assistance in isolating and resolving problems with the GUI.
This section covers GUI access issues that allow you to isolate and resolve GUI
problems. This section extends beyond the GUI in the case where a file module is
not responding and requires a management switchover to the other file module.
Accessing the GUI is critical to isolating and resolving system problems.
1.
Does the GUI launch and are there problems logging into the system?
v
Yes
: Check that the user ID being used was set up to access the GUI. Refer to
“Authentication basic concepts” in the
IBM Storwize V7000 Unified Information
Center
.
v
No
: Proceed to next question.
2.
Does the GUI launch and are there problems logging into the system?
v
Yes
: Verify that you are using a supported browser and the browser settings
are correct. Refer to “Checking your web browser settings for the
management GUI” in the
IBM Storwize V7000 Unified Information Center
.
v
No
: Proceed to next question.
Note:
If the GUI does not load complete these steps.
3.
Are you able to initiate an ssh connection to either file node and log in to
either file node?
v
Yes
:
a.
Run the CLI command
lsnode
and determine the status of the file nodes.
b.
If the
lsnode
reports the management service is not running, refer to
“Management node role failover procedures” on page 157.
c.
If
lsnode
provides the system configuration information, check the
connection status under the appropriate heading. Is the status set to
OK
:
Note:
The Sample Output shown has been adjusted in regards to spacing
and layout to accommodate this publication. It might not match exactly
what is seen on your system.
Sample Output:
[[email protected] ~]# lsnode
Product
Connection
GPFS
CTDB
Hostname
IP
Description
Role
version
status
status
status
Last updated
mgmt001st001 172.31.8.2 active
management,
1.3.0.0-51c
OK
active
active
9/19/11 8:02 AM
management
interface,
node
storage
mgmt002st001 172.31.8.3 passive
management,
1.3.0.0-51c
OK
active
active
9/19/11 8:02 AM
management
interface,
node
storage
EFSSG1000I The command completed successfully.
–
Yes
: Run the CLI command
lshealth
. Reference the active
management node Hostname (mgmt001st001 or mgmt002st002)
obtained from the
lsnode
command. Ensure that HOST_STATE,
SERVICE, and NETWORK from
lshealth
is set to OK.
Chapter 3. Getting started troubleshooting
21
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...