![IBM Storwize V7000 Problem Determination Manual Download Page 28](http://html.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_problem-determination-manual_4062780028.webp)
Table 4. Access information for your system (continued)
Item
Value
Notes
File module 2 service IP
address
The root password for the
file modules (the default is
Passw0rd
)
The control enclosure
management IP address
The control enclosure
superuser password (the
default is
passw0rd
)
Control enclosure canister 1
service IP address
Control enclosure canister 2
service IP address
Follow power management procedures
Access to your volume data can be lost if you incorrectly power off all or part of a
system.
Use the management GUI or the CLI commands to power off a system. Using
either of these methods ensures that the system fails properly in the case of
powering down individual file modules and that data that is cached in the node
canister memory is correctly flushed to the RAID arrays for the disk system.
The Storwize V7000 Unified system uses a pair of file modules for redundancy.
Follow the appropriate power down procedures to minimize impacts to the system
operations. See “Turning off the system” in the Storwize V7000 Unified
information center.
Do not power off an enclosure unless instructed to do so. If you power off an
expansion enclosure, you cannot read or write to the drives in that enclosure or to
any other expansion enclosure that is attached to it from the SAS ports. Powering
off an expansion enclosure can prevent the control enclosure from flushing all the
data that it has cached to the RAID arrays.
Set up event notifications
Configure your system to send notifications when a new event is reported.
Correct any issues reported by your system as soon as possible. To avoid
monitoring for new events that use the management GUI, configure your system
to send notifications when a new event is reported. Select the type of event that
you want to be notified about. For example, restrict notifications to just events that
require immediate action. Several event notification mechanisms exist:
v
Email. An event notification can be sent to one or more email addresses. This
mechanism notifies individuals of problems. Individuals can receive notifications
wherever they have email access which includes mobile devices.
v
Simple Network Management Protocol (SNMP). An SNMP trap report can be
sent to a data-center management system, such as IBM Systems Director, that
4
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...