5.
Issue the following command to view the current setting of the serial number:
asu show SYSTEM_PROD_DATA.SysInfoSerialNum
6.
Issue the following ASU command on the Storwize V7000 Unified node to set
the serial number:
asu set SYSTEM_PROD_DATA.SysInfoSerialNum
xxxxx
The variable
xxxxx
in the command stands for the serial number.
7.
Issue the following command to verify that you set the serial number correctly:
asu show SYSTEM_PROD_DATA.SysInfoSerialNum
How to reset/reboot server iMM interface
Use this procedure to initiate a reset/reboot of the iMM interface located on the
file module. This action is not disruptive to the system operations and should only
be used when directed to clear out fault conditions.
Note:
This procedure requires root access to the file module node.
1.
Log into the active management file module using root.
2.
If this is the file module requiring action, then continue with step 3. If this is
not thefile module to reset:
a.
Type
ssh <node name>
and press
Enter
. For example:
ssh mgmt002st001
3.
Type
asu rebootimm --kcs
and press
Enter
.
Note:
If you are using a telnet connection, you can reboot using resetsp.
a.
Wait for the IMM reboot to complete (typically about 3 minutes). If the
reboot is successful, the output of the previous command will be similar to
the following:
IBM Advanced Settings Utility version 3.62.71B
Licensed Materials - Property of IBM
(C) Copyright IBM Corp. 2007-2010 All Rights Reserved
Try to connect to the primary node to get nodes number.
Connected via IPMI device driver (KCS interface)
Connected to primary node.
Nodes number is 1
Unable to locate a script required to set up LAN-over-USB device, tried location cdc_interface.sh
Connect to imm to reboot.
Issuing reset command to imm.
Checking if the imm has reset yet. (attempt 0)
imm has started the reset.
Disconnect from imm
b.
Wait for about 2 minutes to allow the iMM to completely reboot.
File module software problems
This section helps you to identify and resolve file module software problems.
Logical devices and physical port locations
Use this table to help identify logical devices, file module roles used, and physical
locations.
Table 36. Storwize V7000 Unified logical devices and physical port locations
Logical Ethernet
device name
Device description
Physical location information
mgmtsl0_0
Internal connection between the file modules Port 1 - Built-In xSeries Ethernet Port
156
Storwize V7000 Unified: Problem Determination Guide Version
Summary of Contents for Storwize V7000
Page 6: ...vi Storwize V7000 Unified Problem Determination Guide Version...
Page 8: ...viii Storwize V7000 Unified Problem Determination Guide Version...
Page 10: ...x Storwize V7000 Unified Problem Determination Guide Version...
Page 18: ...xviii Storwize V7000 Unified Problem Determination Guide Version...
Page 24: ...xxiv Storwize V7000 Unified Problem Determination Guide Version...
Page 32: ...8 Storwize V7000 Unified Problem Determination Guide Version...
Page 274: ...250 Storwize V7000 Unified Problem Determination Guide Version...
Page 278: ...254 Storwize V7000 Unified Problem Determination Guide Version...
Page 296: ...272 Storwize V7000 Unified Problem Determination Guide Version...
Page 306: ...282 Storwize V7000 Unified Problem Determination Guide Version...
Page 312: ...288 Storwize V7000 Unified Problem Determination Guide Version...
Page 313: ......
Page 314: ...Printed in USA GA32 1057 04...