Monitoring the IBBU with the MegaRAID Configuration Utilities
6-5
Figure 6.3
Battery Module Screen
Most of the Battery Module properties are view-only and are self-
explanatory.
In the lower right corner of the screen are the Auto Learn options. A
learning cycle
is a battery calibration operation performed by the
controller periodically to determine the condition of the battery. You
can change the learn delay interval
(the length of time between
automatic learning cycles)
and the auto learn mode.
Note:
For the best system performance, leave the learn delay
interval and the auto learn mode at their default settings.
6.1.1.1
Setting the Learn Delay Interval
The learn delay interval is the length of the interval between automatic
learning cycles. Perform the following steps to change the interval:
1. Open the drop-down menu in the
Auto Learn Mode
field.
2. Set the learn mode as
Auto
(the default).
3. Change the number of hours in the
Learn Delay Interval
field.