6-14
Using the ServeRAID M5000 Series Battery Assembly
6.3
Resolving a Configuration Mismatch
If the replacement controller has a previous configuration, this message
displays during the power-on self-test (POST):
Unresolved configuration mismatch between disk(s) and NVRAM
on the adapter
A configuration mismatch occurs when the configuration data in the
NVRAM and the configuration data on the drives are different. To resolve
this, update the configuration data in the NVRAM with the data from the
physical disk. To update the configuration data, follow these steps:
1. Press CTRL+M when prompted during boot-up to access BIOS CU.
2. Select
Configure >
View/Add Configuration
.
This gives you the option to view both the configuration on the
NVRAM and on the physical disk.
3. Select the configuration on the drive.
4. Press
ESC
, and select
YES
to update the NVRAM.
5. Press
ESC
to exit, and then reboot the computer.
Summary of Contents for ServeRAID M5014
Page 1: ...ServeRAID M5014 M5015 SAS SATA Controllers USER S GUIDE M a y 2 0 1 2...
Page 7: ...Preface vii...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 34: ...1 18 Overview...
Page 54: ...3 10 ServeRAID M5014 M5015 SAS SATA Controller Characteristics...
Page 62: ...5 6 Installing a ServeRAID M5000 Series Battery Assembly...
Page 80: ...7 4 ServeRAID M5000 Series Battery Assembly Specifications...
Page 87: ...IBM Taiwan product service A 5 A 8 IBM Taiwan product service...
Page 88: ...A 6 Getting Help and Technical Assistance...
Page 89: ...ServeRAID M5014 M5015 SAS SATA Controllers User s Guide B 1 Appendix B Notices...
Page 94: ...B 6 Notices...
Page 95: ...Electronic emission notices B 7...
Page 96: ...B 8 Notices...
Page 104: ...C 6 Glossary of Terms and Abbreviations...
Page 105: ......
Page 106: ...Part number 81Y1027...