Condition
Operational
Non-operational
Heat dissipation
Refer to the Power consumption table
N/A
Operating noise
Maximum: 65 dB
N/A
Power supply specifications (per PSU)
Power supply
model
Maximu
m output
power
rating
(DC)
Input voltage Input line
frequency
Maximu
m input
current
Input line
protection
Maximum inrush
current
XBR-
G250WPSAC-F
250 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
3.5 A
Line fused
50 A peak @ 240 VAC
for <0ms, 10 ms - 150
ms, <15A peak.
50 A peak @ 240 VAC
at cold start for <10ms.
15 A peak for cycles 10
ms - 150 ms. <3.5 A
peak for >150 ms
XBR-
G250WPSAC-R
250 W
100 – 240 VAC
(nominal)
90 – 264 VAC
(range)
50/60 Hz
(nominal)
47 – 63 Hz
(range)
3.5 A
Line Fused 50 A peak @ 240 VAC
for <10 ms, 10 ms -
150 ms, <15 A peak.
50 A peak @ 240 VAC
at cold start for <10
ms.
15 A peak for cycles 10
ms - 150 ms. <3.5 A
peak for >150 ms
Power consumption (typical configuration)
Model name @100 VAC
input
@200 VAC
input
@48 VDC
input
Minimum
number of
power supplies
Notes
SAN64B-6
switch
1.93 A
192 W
655 BTU/hr
0.97 A
190 W
649 BTU/hr
N/A
1 (But, input
current is for 1
PSU. Watts and
BTUs/hr are with
2 PSUs).
Fully configured all ports with
25% traffic rate, fans at high
speed, and input power +/- 5%
tolerance.
84 IBM Storage Networking SAN64B-6: SAN64B-6 Installation, Service, and User Guide
Summary of Contents for SAN64B-6
Page 6: ...vi...
Page 10: ...x...
Page 22: ...xxii IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 60: ...36 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 70: ...46 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 84: ...60 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 92: ...68 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 121: ......
Page 122: ...IBM Part Number 03GM380 SC27 8965 02 1P P N 03GM380...