Faulty blade indicators
Confirm that you need to replace the blade before continuing. The following events
may indicate that a blade is faulty:
v
The status LED on the blade is lit steady amber, or the power LED is not
illuminated.
v
The
slotShow
command does not show that the blade is enabled.
v
errShow - Displays error log messages one at a time.
v
Any of the following messages display in the error log or "show" command
output:
– "Slot unknown" message relating to the blade slot
– FRU: FRU_FAULTY messages for the blade
– FAULTY (xx) with an associated (xx) code used by support
For output examples and additional information on Fabric OS commands, refer to
“Using monitoring commands” on page 85 and the Fabric OS Command Reference.
For more information about error messages, refer to the Fabric OS Message
Reference.
Time and items required for removal and installation
The removal or installation procedure for each blade takes less than 10 minutes.
Removing and restoring transceivers and cables may take longer depending on
how many must be changed. The following items are required for the blade and
filler panel replacement:
v
Electrostatic discharge (ESD) grounding strap
v
Workstation computer
v
Replacement blade or filler panel
v
#1 Phillips screwdriver
v
SFP, SFP+, or SFP28 transceivers (as needed)
v
Optical and copper cables (as needed)
Note:
For information about the transceivers that are qualified for this device, refer
to Chapter 5, “Installing Transceivers and Cables,” on page 57.
Removing a blade
Before you begin
v
Before removing any cables from a blade, note the cable order (identify each
cable by its physical port).
v
It is a good practice to create a table of cable to port mapping for reference.
v
If multiple blades are being replaced, replace one blade at a time.
About this task
Use the following steps to remove a port or extension blade from the unit while
system power is on. This procedure is applicable for all the port and extension
blades supported on the device.
Chapter 7. Port and Extension Blades
111
Summary of Contents for SAN512B-6
Page 2: ......
Page 8: ...vi SAN512B 6 Installation Service and User Guide...
Page 10: ...viii SAN512B 6 Installation Service and User Guide...
Page 12: ...x SAN512B 6 Installation Service and User Guide...
Page 40: ...16 SAN512B 6 Installation Service and User Guide...
Page 60: ...36 SAN512B 6 Installation Service and User Guide...
Page 128: ...104 SAN512B 6 Installation Service and User Guide...
Page 140: ...116 SAN512B 6 Installation Service and User Guide...
Page 170: ...146 SAN512B 6 Installation Service and User Guide...
Page 184: ...160 SAN512B 6 Installation Service and User Guide...
Page 196: ...172 SAN512B 6 Installation Service and User Guide...
Page 208: ...184 SAN512B 6 Installation Service and User Guide...
Page 258: ...234 SAN512B 6 Installation Service and User Guide...
Page 274: ...250 SAN512B 6 Installation Service and User Guide...
Page 285: ......
Page 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...