4.
Disable any serial communication programs running on the workstation (such
as synchronization programs).
5.
Open the terminal emulator application and configure as follows:
v
In a Windows environment:
Table 7. Configuration parameters
Parameter
Value
Bits per second
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
v
In a UNIX environment, enter the string at the prompt:
term /dev/ttyb -9600
If ttyb is already in use, use ttya instead and enter the following string at the
prompt:
term /dev/ttya -9600
When the terminal emulator application stops reporting information, press
Enter
.
You will receive the following login prompt:
CP0 Console Login:
Continue to the next task.
Logging in to the serial console port
To log in to the SAN384B-2 through the serial connection, follow these steps.
1.
Log in to the SAN384B-2 as
admin
. The default password is "
password
." At the
initial login, you are prompted to change the default passwords. Record the
new passwords and keep this information in a secure location. The example
below shows the login without changing the password.
swDir login:
admin
Password:
Please change your passwords now.
Use Control-C to exit or press ’Enter’ key to proceed.
Password was not changed. Will prompt again at next login
until password is changed.
swDir:admin>
2.
(Optional) Modify passwords. To skip modifying the password, press
Ctrl+C
.Passwords can be 8 to 40 characters long. They must begin with an alphabetic
character. They can include numeric characters, the dot (.), and the underscore
(_). Passwords are case-sensitive, and they are not displayed when you enter
them on the command line. For more information on passwords, refer to the
Fabric OS Administrator’s Guide
.
Configuring the IP addresses
The SAN384B-2 requires three IP addresses, which are configured using the
ipAddrSet
command. IP addresses are required for both CP blades (CP0 and CP1)
and for the chassis management IP (displayed under SWITCH with the
ipAddrShow
command).
Note:
The default IP addresses and host names for the SAN384B-2 are as follows:
36
SAN384B-2 Installation, Service, and User Guide
Summary of Contents for SAN384B-2
Page 2: ......
Page 8: ...vi SAN384B 2 Installation Service and User Guide ...
Page 12: ...x SAN384B 2 Installation Service and User Guide ...
Page 14: ...xii SAN384B 2 Installation Service and User Guide ...
Page 16: ...xiv SAN384B 2 Installation Service and User Guide ...
Page 28: ...xxvi SAN384B 2 Installation Service and User Guide ...
Page 32: ...xxx SAN384B 2 Installation Service and User Guide ...
Page 82: ...50 SAN384B 2 Installation Service and User Guide ...
Page 146: ...114 SAN384B 2 Installation Service and User Guide ...
Page 172: ...140 SAN384B 2 Installation Service and User Guide ...
Page 188: ...156 SAN384B 2 Installation Service and User Guide ...
Page 189: ......
Page 190: ... Part Number 98Y2654 Printed in USA GA32 0894 03 1P P N 98Y2654 ...