v
Temperature in both Centigrade and Fahrenheit
Following is an example of
tempShow
output.
chassis:admin> tempshow
Sensor
Slot
Sensor
State
Centigrade
Fahrenheit
ID
Index
===================================================================
1
3
0
Ok
29
84
2
3
1
Ok
47
116
3
3
2
Ok
43
109
4
4
0
Ok
34
93
5
4
1
Ok
53
127
6
1
0
Ok
36
96
7
1
1
Ok
39
102
8
1
2
Ok
33
91
9
1
3
Ok
41
105
10
2
0
Ok
43
109
11
2
1
Ok
44
111
12
2
2
Ok
41
105
13
2
3
Ok
45
113
14
5
0
Ok
31
87
15
5
1
Ok
45
113
16
5
2
Ok
48
118
17
6
0
Ok
31
87
18
6
1
Ok
45
113
19
6
2
Ok
45
113
20
7
0
Ok
29
84
21
7
1
Ok
44
111
22
7
2
Ok
43
109
23
8
0
Ok
30
86
24
8
1
Ok
45
113
25
8
2
Ok
43
109
Note the following about this output:
v
The absent state simply reflects that the blade slot is empty.
v
The sensor index is mainly for support use.
v
Multiple sensors are commonly averaged to determine thresholds used for managing fan speeds or for
determining a high temperature condition that may require that the blade be shut off.
Running diagnostic tests
Diagnostic tests are automatically run during POST to check the status of the device. Any error messages
generated during POST are sent to the error logs and to the serial console, if connected.
Diagnostic tests can also be run manually to test and troubleshoot the hardware and the firmware,
including internal connections and circuitry, transceivers, and port cables. However, diagnostic tests are
generally intended for use by support personnel.
Note:
Error messages do not necessarily indicate that the device requires maintenance.
Each diagnostic test can be implemented by entering the related command through a Telnet or serial
session. For a list of diagnostic tests and commands, refer to the Fabric OS Administrator's Guide.
All diagnostic tests are run at all supported link speeds. They might temporarily lock the transmit and
receive speeds to a specific speed. Some diagnostic tests require interconnecting the ports to each other or
using loopback plugs. If ports are interconnected, the media (cables and transceivers) at each end of the
connection must be of the same type. For example, short wavelength media must be connected to short
wavelength media, and likewise with long wavelength media and copper media.
Monitoring the device
111
Summary of Contents for SAN256B-6
Page 6: ...vi SAN256B 6 Installation Service and User Guide...
Page 10: ...x SAN256B 6 Installation Service and User Guide...
Page 22: ...xxii SAN256B 6 Installation Service and User Guide...
Page 24: ...xxiv SAN256B 6 Installation Service and User Guide...
Page 34: ...6 SAN256B 6 Installation Service and User Guide...
Page 72: ...44 SAN256B 6 Installation Service and User Guide...
Page 92: ...64 SAN256B 6 Installation Service and User Guide...
Page 108: ...80 SAN256B 6 Installation Service and User Guide...
Page 152: ...124 SAN256B 6 Installation Service and User Guide...
Page 162: ...134 SAN256B 6 Installation Service and User Guide...
Page 198: ...170 SAN256B 6 Installation Service and User Guide...
Page 206: ...178 SAN256B 6 Installation Service and User Guide...
Page 210: ...182 SAN256B 6 Installation Service and User Guide...
Page 214: ...186 SAN256B 6 Installation Service and User Guide...
Page 218: ...190 SAN256B 6 Installation Service and User Guide...
Page 258: ...230 SAN256B 6 Installation Service and User Guide...
Page 278: ...250 SAN256B 6 Installation Service and User Guide...
Page 286: ...258 SAN256B 6 Installation Service and User Guide...
Page 289: ...WWN card power down replacement 156 Index 261...
Page 290: ...262 SAN256B 6 Installation Service and User Guide...
Page 291: ......
Page 292: ...IBM Part Number 01JC333 Printed in USA SC27 8967 03 1P P N 01JC333...