Table
A-1 (Page 1 of 9). Service Request Numbers
SRN
FRU List
%
Problem
10101
Disk drive module
100
Description: Disk drive motor stopped.
The disk drive module is bad.
Action: If this SRN was received by one
disk drive module only, then exchange
that disk drive module.
10112
None
–
Description: Format degraded. A format
operation has been ended before it has
completed.
Action: Use the Format service aid to
format the disk drive module.
1
xxxx
Disk drive module
Backplane assembly
99
1
Description: Disk drive module error.
Action: Exchange the FRU for a new
FRU.
Note: In this SRN, an
x represents a
digit from 0 to F.
20PAA
Disk drive module
SSA adapter card External
SSA Cables
Backplane assembly
Internal SSA Cable
45
45
6
2
2
Description: An open SSA link has been
detected.
Action: Run the Link Verification service
aid to isolate the failure. If the SSA
service aids are not available:
When the failing device is an SSA
Hot-Swap Disk Drive, go to “SSA
Maintenance Analysis Procedures
(MAPs)” on page 2-35.
When the failing device is not an SSA
Hot-Swap Disk Drive, go to the
service information for that device.
21PAA
to
29PAA
Disk drive module
SSA adapter card
External SSA Cables
Backplane assembly
Internal SSA Cable
45
45
6
2
2
Description: An SSA
threshold-exceeded-link error has
been
detected.
Action: Run the Link Verification service
aid to isolate the failure. If the SSA
service aids are not available:
When the failing device is an SSA
Hot-Swap Disk Drive, go to “SSA
Maintenance Analysis Procedures
(MAPs)” on page 2-35.
When the failing device is not an SSA
Hot-Swap Disk Drive, go to the
service information for that device.
A-6
Service Guide
Summary of Contents for RS/6000 7025 F50 Series
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01 ...
Page 6: ...vi Service Guide ...
Page 14: ...xiv Service Guide ...
Page 16: ...xvi Service Guide ...
Page 18: ...Rear View 1 2 Service Guide ...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7 ...
Page 24: ...System Data Flow 1 8 Service Guide ...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide ...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49 ...
Page 208: ...5 40 Service Guide ...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3 ...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9 ...
Page 222: ...5 Close the door 6 14 Service Guide ...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23 ...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide ...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39 ...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43 ...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1 ...
Page 256: ...7 2 Service Guide ...
Page 278: ...A 16 Service Guide ...
Page 344: ...D 28 Service Guide ...
Page 348: ...E 4 Service Guide ...
Page 357: ...voice phone number B 20 VPD vital product data B 13 VPD vital product data 3 93 Index X 9 ...
Page 358: ...X 10 Service Guide ...
Page 361: ......