2.
Replace the service access cover. For instructions, see “Installing the service access cover on an
8001-22C or 8005-22N system” on page 103.
3.
Place the system into the operating position. For instructions, see “Placing an 8001-22C or 8005-22N
system into the operating position” on page 106.
(L012)
or
CAUTION:
Pinch hazard. (L012)
4.
Reconnect the power cords to the system. For instructions, see “Connecting the power cords to an
8001-12C, 8001-22C, 8005-12N, or 8005-22N system” on page 108.
5.
Start the system. For instructions, see “Connecting the power cords to an 8001-12C, 8001-22C,
8005-12N, or 8005-22N system” on page 108.
6.
If you installed or replaced a PCIe adapter, update the adapter firmware. See http://www.ibm.com/
support/knowledgecenter/HW4P4/p8ei8/p8ei8_update_other_adapter.htm(www.ibm.com/support/
knowledgecenter/HW4P4/p8ei8/p8ei8_update_other_adapter.htm).
7.
Verify the installed part. For instructions, see Verifying a repair (www.ibm.com/support/
knowledgecenter/POWER8//p8ei3/p8ei3_verifyrepair.htm).
Starting and stopping the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
Learn how to start and stop the IBM Power System S821LC (8001-12C), the IBM Power System S822LC
for Big Data (8001-22C), the IBM CS821 (8005-12N), or the IBM CS822 (8005-22N) system to perform a
service action or system upgrade.
Starting the 8001-12C, 8001-22C, 8005-12N, or 8005-22N system
You can use the power button to start the IBM Power System S821LC (8001-12C), the IBM Power System
S822LC for Big Data (8001-22C), the IBM CS821 (8005-12N), or the IBM CS822 (8005-22N) systems.
About this task
Attention:
For safety, airflow purposes and thermal performance, the service access cover must be
installed and fully seated before you power on the system.
You can use this procedure to power on the system; or you can use a console and the IPMI tool to power
on the system.
Procedure
1.
Before you press the power button, ensure that the power supplies are connected to the system unit
and that the power cables are connected to a power source.
2.
Press the power button (7) shown in Figure 60 on page 96 or Figure 61 on page 96. You may have to
press the switch for 0.5 to 3 seconds.
Installing and configuring the system
95
Summary of Contents for Power Systems 8001-22C
Page 1: ...Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C IBM...
Page 2: ......
Page 3: ...Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C IBM...
Page 16: ...xiv Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C...
Page 136: ...120 Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C...
Page 137: ......
Page 138: ...IBM Printed in USA...