Common system attention LEDs and system reference codes
Find LED and system reference code (SRC) information for recovering recover from common installation
problems.
The following table describes LED status behaviors and describes the meaning of each behavior.
Table 6. Common installation system attention LEDs
Front power
status LED
(green)
ac in (green)
dc out (green)
Fault (yellow)
Description
On
On
On
Off
Power is being supplied to the system
and the system is powered on.
Flashing
On
Flashing
Off
Power is being supplied to the system.
Flashing
Off
Flashing
Off
Power is not being supplied to one of
the power supplies, but power is being
supplied to the second power supply,
and the system is in standby mode.
On
Off
Flashing
Off
Power is not being supplied to one of
the power supplies, but power is being
supplied to the second power supply,
and the system is powered on.
Off
Off
Off
Off
Power is not being supplied to either
power supply.
Flashing
On
Off or flashing
On
Power is being applied, but the power
supply is not functioning properly and
the system is in standby mode.
On
On
Off or flashing
On
Power is being applied, but the power
supply is not functioning properly and
the system is powered on.
Flashing
On
On
On
110 volts are being applied. This system
requires 220 volts.
The following table describes SRCs that you might encounter during installation.
Table 7. Common installation SRCs
SRC
Error description
Recovery steps
1000xxx
1100xxx
509Axxx
509Dxxx
50A4xxx
50ADxxx
50B1xxx
ac input and power supply
connections
1.
Verify that power cords are plugged in correctly in
the following locations:
v
Drawer
v
Power distribution unit (PDU), if applicable
v
Battery backup unit (BBU), if applicable
v
Input source power receptacle
2.
Verify that the power supplies are seated and latched
into position.
11002613
Your power voltages do not
match
Ensure that you are using the correct power voltage.
Refer to your server's specifications to learn more about
the power voltage that your server requires.
40
Power Systems: Installing the IBM Power 750 (8408-E8D) and IBM PowerLinux 7R4 (8248-L4T)
Summary of Contents for Power 750 Express 8408-E8D
Page 2: ......
Page 6: ...iv Power Systems Installing the IBM Power 750 8408 E8D and IBM PowerLinux 7R4 8248 L4T...
Page 30: ...18 Power Systems Installing the IBM Power 750 8408 E8D and IBM PowerLinux 7R4 8248 L4T...
Page 42: ...30 Power Systems Installing the IBM Power 750 8408 E8D and IBM PowerLinux 7R4 8248 L4T...
Page 65: ......
Page 66: ...Part Number 00L5075 Printed in USA GI11 9890 01 1P P N 00L5075...