operation, the drive being rebuilt is in the rebuild state, and the logical drive remains
critical until the rebuild operation has been successfully completed.
On IBM servers, when a hot-spare drive is available, the Rebuild operation begins
automatically without the need to replace the failed drive. If more than one drive
fails within the same array, no rebuild takes place. If multiple drives fail in separate
arrays (one physical drive per array), the controller initiates a Rebuild operation for
the logical drives within the array containing the first failed physical drive. This
Rebuild operation is performed on the first hot-spare drive of sufficient size to
become a valid member of the array.
To start a Hot-Swap Rebuild, do the following:
1. Reseat the ServeRAID controller and SCSI cables.
2. Without removing the drive completely, gently remove the physical drive from
the server, using the handle of the hot-swap tray. If necessary, refer to the
documentation that comes with your server on removing a physical drive.
3. Wait 20 seconds to allow the physical drive to completely spin down.
Note: When power is removed from a hot-swap drive, the drive immediately
parks the heads, locks the actuator in the “landing zone”, and begins
spinning down. However, the spinning down of the disk might require up
to 20 seconds after power is removed. Do not move the drive while it is
spinning down. Moving the drive while it is spinning down might damage
the drive.
4. If you are certain there is nothing wrong with the physical drive you removed,
gently reinstall the drive into the server.
Note: If multiple drives fail in separate arrays (one physical drive per array),
then replace each defunct physical drives. If multiple physical drives fail
at the same time within the same array, contact your IBM service
representative.
Make sure the drive is completely installed in the backplane connector.
Note: While it is possible to rebuild a defunct physical drive to an online
physical drive that is defective, avoid doing so.
Otherwise, replace the physical drive with a new drive that is the same size (or
larger) and continue with the Rebuild operation.
Recovering from an incomplete format of a physical drive
During formatting of a physical drive, if the format process is stopped by a system
reset, system shut down, power outage, or by some other means, the physical drive
becomes inoperable.
To enable the physical drive to communicate with the ServeRAID controller again,
do the following:
1. Note the channel of the ServeRAID controller to which the physical drive is
connected.
2. Note the SCSI ID of the physical drive.
3. Use the ipssend format function to restart the format of the physical drive. The
syntax is: ipssend format controller channel sid
where:
Chapter 9. Solving ServeRAID problems
69
Summary of Contents for Netfinity ServeRAID-4L Ultra160
Page 1: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 2: ......
Page 3: ...IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference SC06 P461 10...
Page 12: ...x IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 15: ...Part 1 Installation and configuration Copyright IBM Corp 2000 1...
Page 16: ...2 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 34: ...20 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 50: ...36 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 51: ...Part 2 Utility programs Copyright IBM Corp 2000 37...
Page 52: ...38 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 56: ...42 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 64: ...50 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 68: ...54 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 69: ...Part 3 Maintenance and troubleshooting Copyright IBM Corp 2000 55...
Page 70: ...56 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 93: ...Part 4 Appendixes Copyright IBM Corp 2000 79...
Page 94: ...80 IBM Netfinity ServeRAID 4L Ultra160 SCSI Controller User s Reference...
Page 113: ......