As the replacement node boots up the second time, it might again display
the prompt warning of a system ID mismatch and asking to override the
system ID. You can respond
Y
.
If the giveback is vetoed, you can consider forcing giveback by issuing the
following command:
storage failover giveback -ofnode
partner_node_name
-require-partner-waiting true -override-vetoes true
If you are using Data ONTAP 8.2, see the
Clustered Data ONTAP
High-Availability Configuration Guide
on the IBM N series support website for
information on giveback vetoes.
b.
Enter the following command from the healthy node:
storage failover giveback -ofnode
replacement_node_name
As the replacement node boots up, it might again display the prompt
warning of a system ID mismatch and asking to override the system ID.
You can respond y. The replacement node takes back its storage and
completes booting up to the Data ONTAP prompt.
c.
Enter the
storage failover show-giveback
command to monitor the
progress of the giveback operation.
d.
Wait until the
storage failover show-giveback
command output indicates
that the giveback operation is complete.
e.
Enter the
storage failover show
command to confirm that the HA pair is
healthy and takeover is possible. The output from the
storage failover
show
command should not include the "System ID changed on partner"
message.
8.
Verify that the disks (or gateway LUNs) were assigned correctly by entering the
following command:
storage disk show -sanown
Make sure that the disks belonging to the replacement node show the new
system ID for the replacement node. In the following example, the disks owned
by node2 now show the new system ID, 1873774574:
node1> storage disk show -sanown
Disk
Aggregate Home
Owner
Home ID
Owner ID
Reserver
--------
--------- ----------- ------------- ----------- ---------- -----------
node2:0b.17
aggr1
node2
node2
1873774574
1873774574 1873774574
node1:0a.17
aggr1
node1
node1
118065578
118065578
118065578
.
.
.
9.
Verify that the expected volumes are present for each node by entering the
following command:
vol show -node
node-name
Manually reassigning the system ID on a stand-alone system in clustered Data
ONTAP:
In a stand-alone system, you must manually reassign disks to the new controller's
system ID and set the bootarg.init.boot_clustered bootarg before you return the
system to normal operating condition.
About this task
This procedure applies only to systems that are:
v
Operating in clustered Data ONTAP.
Chapter 5. Replacing N7000 series system devices
123
Summary of Contents for N7800
Page 2: ......
Page 12: ...x IBM System Storage N7000 Series Hardware and Service Guide...
Page 18: ...xvi IBM System Storage N7000 Series Hardware and Service Guide...
Page 20: ...xviii IBM System Storage N7000 Series Hardware and Service Guide...
Page 42: ...16 IBM System Storage N7000 Series Hardware and Service Guide...
Page 46: ...20 IBM System Storage N7000 Series Hardware and Service Guide...
Page 54: ...28 IBM System Storage N7000 Series Hardware and Service Guide...
Page 162: ...136 IBM System Storage N7000 Series Hardware and Service Guide...
Page 164: ...138 IBM System Storage N7000 Series Hardware and Service Guide...
Page 168: ...142 IBM System Storage N7000 Series Hardware and Service Guide...
Page 181: ......
Page 182: ...Printed in USA GC26 7953 13...