Installing Parallel Channel Cables
1 Before you start
Attention
Before installing the channel interface cables press
the cable contacts tightly against the ESD pad as
shown, to remove static charge and prevent
possible channel card damage.
An ESD wristband (part 6428167) must be used
while handling channel cables, wrap blocks, and
terminators in the following procedures.
In order to avoid damaging connector, use flat
blade screwdriver 1650853 (3/16 blade x 8"
handle) when installing the parallel channel cable
to the channel card connector.
2 Locating the cables
Note:
The parts shipped are customer order for the devices to be installed.
Table
6-1. Parallel Channel Cable styles
Part
Number
Length m
(ft)
Description
12K0406
2.1 (6.9)
Entitled as a translation cable to connect to existing standard OEMI cables.
3 Connecting interface cables
Perform the following steps on
one
adapter cable
at a time.
1. Connect the Parallel interface cable to the
Parallel Channel Adapter card.
Note:
Use Charts “Locating the correct
CHPID on the card.” on page 6-36
to locate the correct CHPID for the
feature you are working with.
Chapter 6. Completing the Installation
6-33
Summary of Contents for Multiprise 3000 S/390
Page 1: ...S 390 Multiprise 3000 Enterprise Server R IBM Installation Manual SY24 6154 03...
Page 2: ......
Page 3: ...S 390 IBM Installation Manual SY24 6154 03...
Page 8: ...vi Installing the System...
Page 14: ...xii Installing the System...
Page 34: ...1 20 Installing the System...
Page 40: ...2 6 Installing the System...
Page 78: ...5 20 Installing the System...
Page 156: ...6 78 Installing the System...
Page 160: ...7 4 Installing the System...
Page 172: ...B 4 Installing the System...
Page 173: ......
Page 175: ...Spine information IBM S 390 Installation Manual...