Table
12.
Failing
power
supply
for
FC
5095
and
FC
0595
See
Reference
code
Position
00AC
Replace
P01-P02
until
the
failing
unit
is
found.
1510
P02
1520
P01
This
ends
the
procedure.
11.
Perform
the
following:
a.
Disconnect
the
ac
line
cords
from
the
power
outlet.
b.
Use
a
multimeter
to
measure
the
ac
voltage
at
the
customer’s
ac
power
outlet.
Is
the
ac
voltage
from
200
V
ac
to
240
V
ac?
On
a
FC
5095
the
ac
voltage
may
also
be
100
V
to
127
V
ac.
v
Yes
:
Exchange
the
failing
ac
line
cord
or
ac
jumper
cord.
This
ends
the
procedure.
v
No
:
Perform
the
following:
a.
Inform
the
customer
that
the
ac
voltage
at
the
power
outlet
is
not
correct.
b.
Reconnect
the
ac
line
cords
to
the
power
outlet
after
the
ac
voltage
at
the
power
outlet
is
correct.
This
ends
the
procedure.
POWER
PIP11
instructions
for
Models
830,
840,
870,
890,
SB2,
and
SB3
1.
Are
the
ac
line
cords
from
the
failing
tower
or
unit
to
the
customer’s
ac
power
outlet
connected
and
seated
correctly
at
both
ends?
v
Yes
:
Is
the
SRC
1xxx-00AC?
–
Yes
:
Continue
with
the
next
step.
–
No
:
Go
to
step
5
(See
page
.
v
No
:
Connect
the
ac
line
cords
correctly
at
both
ends.
This
ends
the
procedure.
2.
Is
the
SRC
1xxx-00AC
with
the
system
powered
on?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Exchange
the
SPCN
card
-
see
Symbolic
FRU
This
ends
the
procedure.
3.
Perform
the
following:
a.
Disconnect
the
ac
line
cords
from
the
customer’s
ac
power
outlets.
b.
Use
a
multimeter
to
measure
the
ac
voltage
at
the
customer’s
ac
power
outlets.
Is
the
ac
voltage
from
200
V
ac
to
240
V
ac
or
(for
Models
870
or
890
processor
units)
432
V
ac
to
508
V
ac?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Perform
the
following:
a.
Inform
the
customer
that
the
ac
voltage
at
the
power
outlet
is
not
correct.
b.
Reconnect
the
ac
line
cords
to
the
power
outlet
after
the
ac
voltage
at
the
power
outlet
is
correct.
This
ends
the
procedure.
4.
Perform
the
following:
a.
Reconnect
the
ac
line
cords
to
the
power
outlet.
b.
Disconnect
the
ac
line
cords
from
both
AC
modules
or
unit
connectors.
182
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and