Error
code
Description
Action
1xxx
A
microcode
checksum
error
occurred.
1.
Reseat
the
ServeRAID
controller.
2.
Replace
the
ServeRAID
controller.
2xxx
A
code
DRAM
error
occurred.
1.
Install
the
download
jumpers,
flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
Then,
remove
the
jumpers.
2.
Reseat
the
ServeRAID
controller.
3.
Replace
the
ServeRAID
controller.
3000-31xx
A
code
DRAM
error
occurred.
1.
Install
the
download
jumpers,
flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
Then,
remove
the
jumpers.
2.
Reseat
the
ServeRAID
controller.
3.
Replace
the
ServeRAID
controller.
3200
A
code
DRAM
error
occurred.
1.
Install
the
download
jumpers,
flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
Then,
remove
the
jumpers.
2.
Reseat
the
ServeRAID
controller.
3.
Replace
the
ServeRAID
controller.
3300
A
ServeRAID-8i
controller
error
occurred.
Install
the
ServeRAID-8i
controller
in
an
extended
PCI
expansion
slot.
See
the
documentation
that
comes
with
the
computer
and
the
ServeRAID
controller
documentation
for
more
information.
3E20
A
ServeRAID-8i
controller
error
occurred.
1.
Remove
the
ServeRAID-8i
controller
from
its
slot
and
install
it
in
the
proper
PCI-X
option
slot.
2.
Make
sure
that
the
ServeRAID-8i
controller
is
supported
in
this
computer.
3.
Replace
the
ServeRAID-8i
controller.
4.
(Trained
service
technician
only)
Replace
the
system
board.
3E2x
A
ServeRAID-8i
controller
error
occurred.
1.
Reseat
the
ServeRAID
controller.
2.
Flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
3.
Replace
the
ServeRAID-8i
controller.
4.
Integrated
RAID
controller
on
computer.
Chapter
2.
Diagnostics
59
Summary of Contents for IntelliStation M Pro 6218
Page 1: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 8: ...vi IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 16: ...xiv IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 26: ...10 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 140: ...124 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 162: ...146 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 167: ......