SPCN
Error
Codes
Attention:
If
you
replace
FRUs
or
perform
an
action
on
an
I/O
subsystem
and
the
problem
is
still
not
corrected,
go
to
unless
you
were
already
directed
to
any
MAP
154
x
by
the
error
code.
Otherwise,
call
support
if
the
action(s)
for
an
error
code
do
not
resolve
the
problem.
Attention:
If
the
error
code
that
brought
you
to
this
chapter
originated
in
the
operating
system
error
log,
be
aware
that
an
error
may
require
an
additional
15
minutes
to
be
propagated
to
the
operating
system
error
log.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
and
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Error
Code
Description
Action/
Possible
Failing
FRU
1010
xxxx
An
undefined
error
has
occurred
in
the
power
subsystem.
Call
service
support.
1011
00AC
Last
power-down
was
the
result
of
loss
of
AC.
Informational
message
1011
00CA
Thermal
calibration
in
progress
Has
this
code
been
displayed
longer
than
15
minutes?
YES
Reboot
the
system.
The
code
will
be
cleared
when
the
system
successfully
reboots.
NO
Wait
until
this
code
has
been
displayed
for
15
minutes
to
allow
thermal
calibration
to
complete.
The
system
will
not
IPL
while
thermal
calibration
is
in
progress.
1011
3100
I2C
Controller
Primary
I/O
book
Location:
U1.18-P1-H2
1011
3101
1.
I2C
bus
1
fault
2.
Operator
panel
3.
Operator
panel
cable
1.
Primary
I/O
book
Location:
U1.18-P1-H2
2.
Operator
panel
Location:
U1.17-L1
3.
Operator
panel
cable
Location:
U1.17-L1/Q1#
1011
3102
I2C
bus
2
fault
Primary
I/O
book
Location:
U1.18-P1-H2
1011
3104
I2C
bus
4
fault
Primary
I/O
book
Location:
U1.18-P1-H2
1011
3106
I2C
bus
6
fault
Primary
I/O
book
Location:
U1.18-P1-H2
1011
3113
RIO
Bus
Adapter
Primary
I/O
book
Location:
U1.18-P1-H2
422
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...