Optional-device
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
x3650
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
(Trained
service
technician
only)
,
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
An
IBM
optional
device
that
was
just
installed
does
not
work.
1.
Make
sure
that:
v
The
device
is
designed
for
the
server
(see
eserver/serverproven/compat/us/).
v
You
followed
the
installation
instructions
that
came
with
the
device
and
the
device
is
installed
correctly.
v
You
have
not
loosened
any
other
installed
devices
or
cables.
v
You
updated
the
configuration
information
in
the
Configuration/Setup
Utility
program.
Whenever
memory
or
any
other
device
is
changed,
you
must
update
the
configuration.
2.
Reseat
the
device
that
you
just
installed.
3.
Replace
the
device
that
you
just
installed.
An
IBM
optional
device
that
used
to
work
does
not
work
now.
1.
Make
sure
that
all
of
the
hardware
and
cable
connections
for
the
device
are
secure.
2.
If
the
device
comes
with
test
instructions,
use
those
instructions
to
test
the
device.
3.
Reseat
the
failing
device.
4.
Follow
the
instructions
for
device
maintenance,
such
as
keeping
the
heads
clean,
and
troubleshooting
in
the
documentation
that
comes
with
the
device.
5.
Replace
the
failing
device.
36
DR550
Version
4.5
Problem
Determination
and
Service
Guide
Summary of Contents for DR550
Page 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 2: ......
Page 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Page 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Page 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Page 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Page 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Page 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Page 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Page 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Page 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Page 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Page 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Page 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Page 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Page 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Page 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Page 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Printed in USA GA32 0576 00...