Troubleshooting problems in the DCS3860 storage system
Table 20. Troubleshooting
Problem
indicator
Component
Possible cause
Possible solutions
Amber LED is lit
Drive (drive
fault LED)
Drive failure
Replace the failed drive. See
“Replacing components” on page
77 for more information.
Drive uncertified
Verify the drive and part number
to ensure that it is supported by
the DCS3860. See
http://www.ibm.com/systems/
storage/disk
storage
controller
(service action
required LED)
controller failure
Replace the controller. See
“Replacing components” on page
77 for more information.
The controller was
placed offline by a
user or the other
controller.
Use the Subsystem Management
window to place the controller
back online. If the controller
continues going to an offline state
after being placed online, replace
the controller.
storage
controller
(battery fault
LED)
Battery unit failure
Use the Storage Manager
software to confirm the failure;
then, replace the failed battery
unit.
storage
controller (SAS
link service
action LED)
SAS cable failure
Replace the SAS cable.
SAS host bus
adapter failure
Check the SAS host bus adapter
in the host and replace the
adapter if necessary.
SAS port failure
Replace the controller. See
“Replacing components” on page
77 for more information.
Front bezel
(system error
LED)
General machine
fault
A fault LED is lit somewhere on
the storage system (check for
amber LEDs on components).
General machine
fault (continued)
Open the Subsystem Management
window and click
Recovery Guru
to see problems in the DCS3860
configuration.
Some errors cause the system
error LED to be lit but not cause
any individual component fault
LEDs to be lit. (Drive PFA
exceeded or nominal temperature
exceeded errors are examples.)
Follow the corrective actions in
the Recovery Guru window.
124
IBM System Storage DCS3860 Storage System: Installation, User's, and Maintenance Guide
Summary of Contents for DCS3860
Page 6: ...vi IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 8: ...viii IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 42: ...24 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 72: ...54 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 94: ...76 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 140: ...122 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 158: ...140 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 162: ...144 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 166: ...148 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 174: ...156 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 178: ...160 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 202: ...184 IBM System Storage DCS3860 Storage System Installation User s and Maintenance Guide...
Page 203: ......
Page 204: ...Part Number 46W6954 Printed in USA SC27 5942 00 1P P N 46W6954...