|
0|
1:4|
DQR9P6C00D1H|
33GB|
--|
UNA|
U|
Dismounted|
1|
1|
0|
|
1|
1:5|
DQR9P6C00D3F|
33GB|
DG2|
GRP|
OK|
Mounted|
1|
1|
0|
|
2|
2:6|
DQR9P6C00D8S|
33GB|
DG2|
GRP|
OK|
Mounted|
1|
1|
0|
|
3|
2:2|
DQR9P6C00D8U|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
4|
2:1|
DQR9P6C00D8V|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
5|
2:3|
DQR9P6C00D9A|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
6|
1:6|
DQR9P6C00DBK|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
7|
1:3|
J3XU3MVK|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
8|
1:1|
J3XU3R0K|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
9|
1:2|
J3Y564BK|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
10|
2:4|
J3Y8DVLK|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|
11|
2:5|
J3YWKMKJ|
33GB|
--|
UNA|
OK|
Mounted|
1|
1|
0|
|_______|______|______________|_______|______|_______|_______|_____________|______|______|______|
list pool
The
list pool
command creates output providing summary information, including
the status, about each pool. Any volume service currently running on a pool is also
shown in the status. Size displayed is total and available capacity.
The
state
definitions are:
v
UN
- Unmounted, Non-viable
v
MF
- Mounted, Failed
v
UF
- Unmounted, Failed
v
DN
- Dismounted, Non-viable
v
DF
- Dismounted, Failed
v
UV
- Unmounted, Viable
v
DV
- Dismounted, Viable
v
MV
- Mounted, Viable
v
MN
- Mounted, Non-viable.
Note:
One or more drives are missing in this pool. You must acknowledge an
alert pertaining to this state. If the missing drive comes back to make the pool
viable, the state automatically changes to
MV
. When you acknowledge the alert,
the state of the pool becomes
UN
.
Command arguments:
<CLI> list pool
Example:
<CLI> list pool
_____________________________________________________________________________________________
|Pool#| ID | Name |RaidType|OwnerCtlr|TotalCap|AvailCap|
Status
|State |Degraded|
|_____|____|______|________|_________|________|________|_____________________|______|________|
|
0|
1|
DG1|
5|
IO 3|
267GB|
117GB|Degraded-InTransition|
MV|
Yes|
|_____|____|______|________|_________|________|________|_____________________|______|________|
Chapter 8. Using the RAID Controller command line interface
57
Summary of Contents for BladeCenter S SAS RAID Controller Module
Page 2: ......
Page 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Page 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Page 209: ...Taiwan Class A compliance statement Notices 199...
Page 215: ......
Page 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...