4.
Verify that the installation of the I/O-module type is supported by the
BladeCenter unit and blade server hardware.
5.
Verify that the I/O modules for the network interface are installed in the
correct BladeCenter bays.
6.
Verify that the I/O modules for the network interface are configured correctly.
7.
Verify that the settings in the I/O module are correct for the blade server.
Some settings in the I/O module are specifically for each blade server.
8.
Verify that the I/O modules for the network interface are operating correctly.
Troubleshoot and replace the I/O module as indicated in the documentation
for the I/O module.
9.
Verify that the management module is operating correctly.
See the online information center or the
Problem Determination and Service
Guide
or the
Hardware Maintenance Manual and Troubleshooting Guide
for your
BladeCenter unit.
Some BladeCenter unit types have several management-module components
that you might test or replace. See the online information or the
Installation
Guide
for your management module for more information
10.
Replace the management module.
See the online information center or the
Problem Determination and Service
Guide
or the
Hardware Maintenance Manual and Troubleshooting Guide
for your
BladeCenter unit.
If these steps do not resolve the problem, it is likely a problem with the blade
server. See “Network connection problems” on page 200 for more information.
Solving shared power problems
Problems with BladeCenter shared resources might appear to be in the blade
server, but might actually be a problem in a BladeCenter unit power component.
To check the general function of shared BladeCenter power resources, perform the
following procedure.
1.
Verify that the LEDs on all the BladeCenter power modules are lit.
2.
Verify that power is being supplied to the BladeCenter unit.
3.
Verify that the installation of the blade server type is supported by the
BladeCenter unit.
4.
Verify that the power configuration of the BladeCenter unit supports the blade
bay where your blade server is installed. See the online documentation for your
BladeCenter unit.
5.
Verify that the BladeCenter unit power management configuration and status
support blade server operation.
See the online information for your management module or the
Management
Module User’s Guide
or the
Management Module Command-Line Interface Reference
Guide
for more information.
Chapter 2. Diagnostics
229
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...