Preparing to install a disk drive or solid-state drive by using the
iprconfig command
Complete the following steps before installing a disk drive or solid-state drive in a system or in an
expansion unit:
1.
Log in as root user.
2.
Type
iprconfig
on the command line of the Linux session, and then press
Enter
. The IBM Power
RAID Configuration Utility display is shown.
3.
Select
Work with disk unit recovery
from the IBM Power RAID Configuration Utility display. Press
Enter
.
4.
Select
Concurrent add device
from the Work with Disk Unit Recovery display. Press
Enter
.
A Concurrent Device Add display, similar to the following figure, is shown.
5.
Type
t
if you want to toggle through different location code representations.
6.
Type
1
next to the location into which you want to install the disk drive or solid-state drive and press
Enter.
The Verify Device Concurrent Add display is shown.
A service indicator flashes for the slot where the disk drive or solid-state drive can be installed.
Select from the following options:
v
If you are installing a drive in a system or in an expansion unit, go to “Installing a disk drive or
solid-state drive in the 8248-L4T, 8408-E8D, or 9109-RMD system or expansion unit” on page 13.
v
If you are installing a drive in the 5887 disk drive enclosure, go to “Installing a disk drive or solid-state
drive in the 5887 disk drive enclosure” on page 14.
v
If you are installing a drive in the EDR1 PCIe storage enclosure, go to “Installing a solid-state drive in
the EDR1 PCIe storage enclosure” on page 14.
Concurrent Device Add
Choose a single location for add operations
1=Select
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- -----------------
U5887.001.Z065075-P1-D1
Empty
U5887.001.Z065075-P1-D6
Empty
U5887.001.Z065075-P1-D7
Empty
U5887.001.Z065075-P1-D8
Empty
U5887.001.Z065075-P1-D9
Empty
e=Exit
q=Cancel
t=Toggle
Figure 4. Example Concurrent Device Add display
12
Disk drives or solid-state drives
Summary of Contents for 8248-L4T
Page 1: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Page 2: ......
Page 3: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Page 10: ...viii Disk drives or solid state drives...
Page 18: ...2 Disk drives or solid state drives...
Page 70: ...54 Disk drives or solid state drives...
Page 90: ...74 Disk drives or solid state drives...
Page 94: ...78 Disk drives or solid state drives...
Page 98: ...82 Disk drives or solid state drives...
Page 142: ...126 Disk drives or solid state drives...
Page 144: ...128 Disk drives or solid state drives...
Page 148: ...132 Disk drives or solid state drives...
Page 158: ...142 Disk drives or solid state drives...
Page 162: ...146 Disk drives or solid state drives...
Page 198: ...182 Disk drives or solid state drives...
Page 202: ...186 Disk drives or solid state drives...
Page 212: ...196 Disk drives or solid state drives...
Page 213: ......
Page 214: ...Printed in USA...