Table 2. Light path diagnostics panel LEDs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, "Parts listing", in the
Problem Determination and Service Guide
to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If a action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
LED
Description
Action
OVER SPEC
(Continued)
The power supplies are using
more power than their maximum
rating.
If the 12 V channel C error LED is lit, complete the following
steps:
1. Turn off the server and disconnect the power from the
server.
2. Remove the SAS/SATA RAID riser card, DIMMs in
connectors 1 through 8, and the microprocessor in socket
1.
Note:
The server will not power-on when the
microprocessor in socket 1 or 2 is not installed in the
server. Do the following, depending on the level of your
system board:
v
For the pass 8 level system board
, (trained service
technician only) toggle the switch block (SW4), bit 8 to
allow the server to power-on. See Table 5 on page 40
for the location of the SW4 switch block on the pass 8
level system board.
v
For the pass 9 level system board
, (trained service
technician only) toggle the switch block (SW4), bit 3 to
allow the server to power-on. See Table 8 on page 43
for the location of the SW4 switch block on the pass 9
level system board.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that you removed in step 2 one at a
time, starting the server each time, to isolate the failing
device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system
board.
(Continued on the next page.)
Chapter 1. The System x3550 M2 server
19
Summary of Contents for 79463AU
Page 1: ...IBM System x3550 M2 Types 4198 and 7946 Installation and User s Guide...
Page 2: ......
Page 3: ...IBM System x3550 M2 Types 4198 and 7946 Installation and User s Guide...
Page 8: ...vi IBM System x3550 M2 Types 4198 and 7946 Installation and User s Guide...
Page 134: ...118 IBM System x3550 M2 Types 4198 and 7946 Installation and User s Guide...
Page 140: ...124 IBM System x3550 M2 Types 4198 and 7946 Installation and User s Guide...
Page 141: ......
Page 142: ...Part Number 81Y6100 Printed in USA 1P P N 81Y6100...