29.
Return to your terminal and the IBM i sign on screen.
30.
Select
Power on domain
on the Hardware Resource Concurrent Maintenance display and press
Enter.
31.
Select
Assign
to on the resource that has an asterisk (*) on the Work with Controlling Resource
display. Press Enter.
32.
Wait for the Hardware Resource Concurrent Maintenance display to appear with this message:
Power
on complete
The device is now configured.
This ends this procedure.
Removing and replacing a PCI adapter contained in a cassette in a
Linux partition that is powered on
Procedures performed on a PCI adapter in a Linux partition that is powered on, also known as hot-plug
procedures, require the system administrator to take the PCI adapter offline prior to performing the
operation. Before taking an adapter offline, the devices attached to the adapter must be taken offline as
well. This action prevents a service representative or user from causing an unexpected outage for system
users.
Before performing this procedure, do the following steps:
Figure 24. PCI adapter EMC shield in the closed position
5790 and 7311 model D11 removal and replacement procedures
37