7012 POWERstation and POWERserver 34H, 355, 360, 365, 370, and
375
Dimensions
Desktop
Deskside
Height
162 mm 6.4 in.
466 mm 18.3 in.
Width (at pedestal
456 mm 18.0 in.
241 mm 9.5 in.
for deskside)
Depth
523 mm 20.6 in.
523 mm 20.6 in.
Weight
Minimum
12.7 kg 28 lbs.
12.7 kg 28 lbs.
Maximum
15.4 kg 34 lbs.
15.4 kg 34 lbs.
Electrical
Power source loading
0.29
(typical in kVA)
Voltage range (V ac)
100 to 125 or 200 to 240 (autoranging)
Frequency (hertz)
50 or 60
Thermal output
(typical)
585 Btu/hr
Power requirements
(typical)
185 watts
Power factor
0.5 to 0.7
Inrush current
49 amps at 120 V ac, 98 amps at 240 V ac
Maximum altitude
2135 m (7000 ft.)
Temperature
Requirements
Operating
16 to 32°C
(60 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity
Requirements
Operating
Non-Operating
(Noncondensing)
8 to 80%
8 to 80%
Wet Bulb
23°C (73°F)
27°C (80°F)
Noise Emissions
¹
Operating
Idle
L
WAd
5.7 bels
5.5 bels
L
pAm
45 dBA
45 dBA(desktop)
N/A
N/A (deskside)
<L
pA
>
m
41 dBA
41 dBA (desktop)
38 dBA
38 dBA(deskside)
Impulsive or
prominent discrete
tones
No
No
Clearances
Front
Back
Left
Right
Install/Air Flow
²
152 mm(6 in)
152 mm(6 in)
N/A
N/A
Service
760 mm(30 in)
N/A
N/A
N/A
Footprint
2
Width
Depth
Desktop
456 mm(18 in)
830 mm(33 in)
Deskside
241 mm(9.5 in)
828 mm(32.6 in)
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
18
Site and Hardware Planning Information
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...