Chapter 5. Physical Characteristics of the 2100 Series
This chapter provides the physical characteristics for the 2100 series of external devices. The following
information can help you plan for your external devices. You need only do physical planning for the
devices you have ordered.
Note:
Footprints are not drawn to scale. Where a footprint is shown, the figure represents a top view of
the device.
2101, 2102, and 2103 Fibre Channel RAID Storage Subsystem
2101 Model 100 Seascape Solution Rack
Dimensions
Height
1580 mm
62.0 in.
Width
650 mm
25.5 in.
Depth
1030 mm
36.0 in.
40.5 in.
Weight (empty)
160 kg
352 lbs.
Electrical
Power source loading:
Maximum
operating
2.7 kVA
Voltage range (V ac)
200 to 240
Frequency (hertz)
50 or 60
Thermal output
(Maximum)
9250 Btu/hr
Maximum altitude
2135 m (7000 ft.)
Temperature
Requirements
Operating
10 to 40°C
(50 to 104°F)
Non-Operating
10 to 52°C
(50 to 125°F)
Humidity
Requirements
Operating
Non-Operating
(Noncondensing)
8% to 80%
8% to 80%
Wet Bulb
27°C (80°F)
27°C (80°F)
Noise Emissions*
Operating
Idle
L
WAd
6.6 bels
NA bels
L
pAm
N/A
N/A
<L
pA
>
m
NA dBA
NA dBA
Impulsive or
prominent discrete
tones
N/A
N/A
Clearances
Front
Back
Left
Right
Install/Air Flow
Maintenance of a proper service clearance should allow proper air flow.
Service
915mm(36 in)
915mm(36 in)
915mm(36 in)
915mm(36 in)
* See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
229
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...