Table
2.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
Parts
Listing,
Machine
Type
6217
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
(Trained
service
technician
only),
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
codes
Description
Action
301
and
303
An
error
occurred
during
the
keyboard
and
keyboard
controller
test.
These
error
messages
also
might
be
accompanied
by
continuous
beeping.
1.
If
you
just
connected
a
new
mouse
or
other
pointing
device,
turn
off
the
computer
and
disconnect
that
device.
Wait
at
least
5
seconds;
then,
turn
on
the
computer.
If
the
error
message
goes
away,
replace
the
device.
2.
Make
sure
that
nothing
is
resting
on
the
keyboard
or
pressing
on
a
key.
3.
Make
sure
that
no
key
is
stuck.
4.
Make
sure
that
the
keyboard
cable
is
connected
correctly
to
the
keyboard
and
to
the
correct
connector
on
the
computer.
5.
After
installing
a
USB
keyboard,
run
the
Configuration/Setup
Utility
program
to
enable
keyboardless
operation
and
prevent
the
POST
error
message
from
being
displayed
during
startup.
6.
Reseat
the
following
components:
a.
Keyboard
b.
(Trained
service
technician
only)
System
board
7.
Running
the
diagnostic
tests
can
isolate
the
computer
component
that
failed,
if
the
error
message
remains.
8.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Keyboard
b.
(Trained
service
technician
only)
System
board.
1162
The
serial
port
configuration
conflicts
with
another
device
in
the
system.
1.
Make
sure
that
the
IRQ
and
I/O
port
assignments
needed
by
the
serial
port
are
available.
2.
If
all
interrupts
are
being
used
by
adapters,
remove
an
adapter
to
make
an
interrupt
available
to
the
serial
port,
or
force
other
adapters
to
share
an
interrupt.
3.
Make
sure
that
the
serial
port
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it
and
save
the
setting.
2462
A
video
memory
configuration
error
occurred.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
default
settings.
2.
Reseat
the
video
adapter.
3.
Replace
the
video
adapter.
Chapter
5.
Solving
problems
61
Summary of Contents for 62174DU - IntelliStation A - Pro 6217
Page 3: ...IntelliStation A Pro Type 6217 Installation Guide...
Page 20: ...8 IntelliStation A Pro Type 6217 Installation Guide...
Page 56: ...44 IntelliStation A Pro Type 6217 Installation Guide...
Page 64: ...52 IntelliStation A Pro Type 6217 Installation Guide...
Page 68: ...56 IntelliStation A Pro Type 6217 Installation Guide...
Page 92: ...80 IntelliStation A Pro Type 6217 Installation Guide...
Page 97: ......
Page 98: ...Part Number 31R1983 Printed in USA 1P P N 31R1983...