background image

ZZ17-W2001-B 

1

YY-W2xx  

Pedestal Server Chassis 

YY-R5xx 

5U Rackmount Server Chassis 

Installation Guide

2005.04. Version B 

Summary of Contents for 5U Rackmount Server Chassis YY-R5xx

Page 1: ...ZZ17 W2001 B 1 YY W2xx Pedestal Server Chassis YY R5xx 5U Rackmount Server Chassis Installation Guide 2005 04 Version B...

Page 2: ...allation 3 6 Instructions for Switches and LED Indicators on front panel 3 7 Instructions for cooling fan assembly 3 8 Rack Mount Sliding Rails Installation 4 1 System Assembly 4 Introduction of IDE S...

Page 3: ...e bays with flexible configuration z A type Supply 8 x 5 25 2 x 3 5 HDD drive bays z B type Supply 5 x 5 25 drive bays and 7 x 3 5 HDD drive bays i e A type plus HDD fixed cage z C type Supply flexibl...

Page 4: ...h Switch z Power On LED Green z HDD LED Orange flash z FAN ALARM Red z LAN LED Green Flash X 2 z Power Fail LED optional reserved for Power Failure Signal z USB Ports X 4 Audio ports Optional Rack Mou...

Page 5: ...ed are included If anything is missing or damage contact your retailer as soon as possible Don t use any uncertified material or components in this system z Chassis A type B type C type ATA IDE SCSI S...

Page 6: ...andoffs required to chassis Put the Motherboard into the chassis than screw in for fixing Next step is to plug the DC ATX 20 or EPS 24 pin connector on the Power Supply to Motherboard and insert the p...

Page 7: ...rd Clamp Holder which is used to clamp the Add on Card for avoiding any popping issue To remove The Clamp Holder first install Add on Cards as usual adjust the holder s height for clamping well the Ad...

Page 8: ...ward z To remove the metal covers vented panel z Screw a pair of rails to drive z Slide in the drive install chassis z Screw in two 2 6 32 on the front plate 3 5 Hard Disk Drive Installation How to us...

Page 9: ...ing fan of HDD cage could be easy swap release two thumb screws in the front of HDD cage lift off the fan holder swap fan and assembly again into cage How to use HDD brackets YY W2 Server Chassis is b...

Page 10: ...system power LED green connect to M B x POWER FAILURE LED Reserved and optional requested it may connected with the Power TTL signal wire supplied by PSU RED The power module is in abnormal operation...

Page 11: ...d be mounted optional two 60x60 cooling fans in rear mounted for strengthen the air flow by pass of Add on Cards 3 8 Rack Mount Sliding Rails Installation YY W2 needs to use 24 rails optional Screw th...

Page 12: ...Then the user can start to install the O S and required software to the system according to the instruction on the manual of Motherboard 4 Introduction of IDE SCSI SATA multi bay backplane modules YY...

Page 13: ...ZZ17 W2001 B 13 5 How to change versatile as Rackmount Chassis 5U 1 To remove top cover and bottom cover of chassis 2 Screw in rack bracket and handles Type A SI 0357 x 1 Type A SI 0237 x 2...

Page 14: ...ZZ17 W2001 B 14 3 Slide into EIA cabinet...

Reviews: