If you want to connect your 5147-024, ESLL, or ESLS storage enclosure to your system, continue
with “Connecting the 5147-024, ESLL, or ESLS storage enclosure to your system” on page 11.
5.
If you need to install the 5147-024, ESLL, or ESLS storage enclosure into a rack, ensure that you have
the following items before you start your installation:
v
Phillips screwdrivers
v
Flat-head screwdriver
v
Rack with two Electronic Industries Alliance (EIA) units of contiguous space.
Note:
If you do not have a rack that is installed, install the rack. For instructions, see Racks and
rack features (http://www.ibm.com/support/knowledgecenter/POWER8/p8hbf/
p8hbf_8xx_kickoff.htm).
Completing inventory for the 5147-024, ESLL, or ESLS storage
enclosure
To complete inventory, complete the steps in this procedure.
1.
Refer to the inventory list, and verify that you received all of the parts that you ordered. At a
minimum, each order contains the following items:
v
Left and right rack-mounting hardware
v
Mounting screws
v
Power supply cables
2.
If your shipment contains parts that are not required to complete the installation procedure, store
those parts in case they are needed in the future.
3.
If you have incorrect, missing, or damaged parts, consult any of the following resources:
v
Your IBM reseller.
v
IBM Rochester manufacturing automated information at 1-800-300-8751 (United States only).
v
See the Directory of worldwide contacts website(http://www.ibm.com/planetwide). Select your
location to view the service and support contact information.
4.
If you have incorrect, missing, or damaged parts, consult your next level of support.
Determining and marking the location in the rack
Learn how to determine where to install the disk drive enclosure into the rack.
Read the Rack safety notices (http://www.ibm.com/support/knowledgecenter/POWER8/p8hbf/
racksafety.htm).
To determine where to install the storage enclosure into a rack, complete the following steps:
1.
Determine where in the rack to place the enclosure in relation to other system hardware. As you plan
for installing the enclosure in a rack, keep in mind the following information:
v
Organize larger and heavier units into the lower part of the rack.
v
Plan to install units into the lower part of the rack first.
v
Record the Electronic Industries Alliance (EIA) locations in your plan.
Note:
The 5147-024, ESLL, and ESLS storage enclosures are two EIA units high. An EIA unit is 44.50
mm (1.75 in) in height. The rack contains three mounting holes for each EIA unit of height. This
enclosure, therefore, is 89 mm (3.5 in) high and covers six mounting holes in the rack.
2.
If necessary, open or remove the front and rear rack doors.
3.
Attach the electrostatic discharge (ESD) wrist strap.
2
Power Systems: Installing the Model 024, ESLL, or ESLS storage enclosure
Summary of Contents for 5147-024
Page 1: ...Power Systems Installing the Model 024 ESLL or ESLS storage enclosure GI11 9921 01 IBM...
Page 2: ......
Page 3: ...Power Systems Installing the Model 024 ESLL or ESLS storage enclosure GI11 9921 01 IBM...
Page 6: ...iv Power Systems Installing the Model 024 ESLL or ESLS storage enclosure...
Page 16: ...xiv Power Systems Installing the Model 024 ESLL or ESLS storage enclosure...
Page 62: ...46 Power Systems Installing the Model 024 ESLL or ESLS storage enclosure...
Page 63: ......
Page 64: ...IBM Part Number 01LK529 Printed in USA GI11 9921 01 1P P N 01LK529...