__
g.
Select
Display
disk
configuration
status
on
the
Display
Disk
Configuration
display.
Mirrored
status
will
show
Resuming
.
When
complete,
the
Mirrored
status
will
show
Active
.
This
process
may
take
several
minutes
to
complete.
You
can
either
monitor
this
display
to
completion,
or
press
F3
(Exit)
repeatedly
to
return
to
the
OS/400
main
menu.
__
h.
Install
the
disk
unit
covers.
Align
the
tabs
on
the
disk
unit
cover
with
the
slots
in
the
system
unit.
Push
the
cover
in
until
it
latches.
__
i.
Install
or
close
the
system
unit
or
expansion
unit
front
cover.
The
replacement
of
the
disk
unit
is
complete.
Replace
43xx
RAID
or
Mirrored
protected
disk
units
with
system
powered
off
To
replace
a
disk
unit
with
the
system
powered
off,
follow
these
steps:
__
1.
For
mirrored
disk
units
,
follow
these
steps
to
verify
that
the
disk
unit
you
are
replacing
has
been
suspended
before
powering
off
the
system:
__
a.
Be
sure
you
are
signed
on
with
at
least
service
level
authority
.
__
b.
Type
strsst
on
the
command
line
of
the
OS/400
session
and
press
Enter.
__
c.
Type
your
service
tools
user
ID
and
service
tools
password
on
the
Start
Service
Tools
(STRSST)
Sign
On
display.
Press
Enter.
Note:
The
service
tools
password
is
case
sensitive.
__
d.
Select
Work
with
disk
units
from
the
System
Service
Tools
(SST)
display.
Press
Enter.
__
e.
Select
Display
Disk
Configuration
from
the
Work
with
Disk
Units
display.
Press
Enter.
__
f.
Select
Display
Disk
Configuration
Status
from
the
Display
Disk
Configuration
display.
Press
Enter.
__
g.
Does
the
disk
unit
that
is
mirrored
to
the
disk
unit
that
you
are
replacing
(same
unit
number)
have
a
status
of
Active
?
__
No
:
Do
NOT
replace
the
disk
unit.
Contact
IBM
or
your
authorized
service
provider.
__
Yes
:
Does
the
disk
unit
that
you
are
replacing
have
a
status
of
Suspended
?
__
Yes
:
Continue
with
the
next
step.
__
No
:
Follow
these
steps
to
suspend
mirrored
protection
on
the
disk
unit
that
you
are
replacing:
1)
Press
F3
from
the
Display
Disk
Configuration
display
to
return
to
the
Work
with
Disk
Units
display.
2)
Select
Work
with
Disk
Unit
Recovery
from
the
Work
with
Disk
Units
display.
Press
Enter.
3)
Select
Suspend
mirrored
protection
from
the
Work
with
Disk
Unit
Recovery
display.
Press
Enter.
4)
Select
the
option
to
Suspend
the
disk
unit
that
you
are
replacing
from
the
Suspend
Mirrored
Protection
display.
Press
Enter.
__
2.
Press
F3
repeatedly
to
exit
System
Service
Tools
and
return
to
the
main
menu.
8
43xx
Disk
Unit,
71xx
Disk
Expansion
Unit,
71xx
Disk
Unit
Enclosure
V5R3
Summary of Contents for 43 Series
Page 1: ...iSeries 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure Version 5 ERserver ...
Page 2: ......
Page 3: ...iSeries 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure Version 5 ERserver ...
Page 6: ...iv 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 34: ...28 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 37: ...270 800 or 810 in a rack Open or remove the front cover 31 ...
Page 41: ...820 system unit Disk unit locations 35 ...
Page 42: ...825 system unit 36 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 60: ...54 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 66: ...60 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 74: ...68 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 76: ...70 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3 ...
Page 85: ......
Page 86: ... Printed in USA ...