Displaying Syslog messages for temperature
The software sends a Syslog message and an SNMP trap if the temperature crosses
the warning or shutdown thresholds. The following methods describe how to view
the system log on the device. If you have configured the device to use a Syslog
server or SNMP trap receiver, see the documentation for the server or receiver.
To display the system log, enter the
show log
command at any CLI level.
FCX648SHPOE Switch# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level 45.0 C
degrees
Changing temperature warning and shutdown levels
The default warning temperatures and the default shutdown temperatures for the
device are:
- Warning temperature is 85° C (measured on mainboard)
- Shutdown temperature is 90° C (measured on mainboard)
Note:
These temperatures reflect the temperature of the board inside the device.
To change the temperature at which the device sends a warning, enter a command
similar to the following at the Privileged EXEC level of the CLI:
FCX624 Router# temperature warning 1 85
Syntax: temperature warning <stack-unit> <value>
<
stack-unit
> can be 1 - 8.
<
value
> can be 0 - 125
To display the current temperature readings, enter the
temp
command as shown.
FCX624S Switch# temperature
temperature
temperature sensor commands
FCX624S Switch# temperature warning
warning
Temperature at which the module sends a warning
FCX624S Switch# temperature warning
DECIMAL
Stack Number
FCX624S Switch# temperature warning 1 87
FCX624S Switch# show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan ok, speed (auto): [[1]]<->2<->3
Fan speed switching temperature thresholds:
1 -> 2 @ 61 deg-C
1 <- 2 @ 56 deg-C
44
Ethernet y-series Installation and User Guide: Installation and User Guide
Summary of Contents for 4002-Y2A
Page 2: ......
Page 8: ...vi Ethernet y series Installation and User Guide Installation and User Guide...
Page 10: ...viii Ethernet y series Installation and User Guide Installation and User Guide...
Page 26: ...xxiv Ethernet y series Installation and User Guide Installation and User Guide...
Page 54: ...28 Ethernet y series Installation and User Guide Installation and User Guide...
Page 82: ...56 Ethernet y series Installation and User Guide Installation and User Guide...
Page 92: ...66 Ethernet y series Installation and User Guide Installation and User Guide...
Page 95: ......
Page 96: ...Part Number 45W7657 Printed in USA GC27 2269 00 1P P N 45W7657 53 1001545 01...