ibaMBox
Manual
Issue 1.3
19
Each input of modules ibaMS8xIEPE and ibaMS8xICP with BNC connector is equipped
with an LED. The LEDs indicate the following states of the measured signal:
LED per channel
Meaning
Green
3 V … 20 V
within measurement range
Red
Wire not connected or broken
7.3
Interfaces and displays
7.3.1
Voltage supply
Power supply feed AC 100/240 V with panel plug for non-heating appliances and switch.
Maximum power consumption 3.0 A (100 V) / 1.5 A (240 V)
Built-in microfuse: 1.6 A / 250 VAC, time-lag
7.3.2
Electrical socket
Built-in socket for the power supply of external devices, such as a notebook.
Power out: max. 250 W
7.3.3
Interfaces of the built-in central unit
The interfaces available here vary depending on the built-in central unit. Please see the
corresponding device manual.
7.3.4
FO connections X10 (TX) and X11 (RX)
X11 (RX): FO receive interface
X10 (TX): FO send interface
Function in the central units, ibaPADU-S-CM, ibaPQU-S, ibaCMU-S (optional)
Measurement and configuration data are exchanged with the external ibaPDA system
(e.g. notebook) through fiber optic connections. An ibaFOB-io-ExpressCard is needed in
the notebook in order to receive and send data.
Function in the ibaDAQ-S central unit
The FO connections function as an ibaFOB-io card. Other iba devices can be connected
via it, such as the ibaPADU family, iba bus monitors and system connections.
The FO connections are designed for cables with 62.5/125 μm multimode fibers with ST
connectors. Suitable FO patch cables are available from iba.
Supported ibaNet protocols of the central units:
32Mbit Flex
32Mbit
5Mbit
3Mbit
ibaPADU-S-CM
-
-
-
ibaCMU-S
-
-
ibaPQU-S
-
-
-
ibaDAQ-S