IBA ibaPADU-16 Manual Download Page 1

 

 

 
 

ibaPADU-8/ -16/ -32/ -32-R 

Manual 

Issue 3.3 

Parallel-Analog-Digital-Converter for 8, 16 or 32 channels 

Summary of Contents for ibaPADU-16

Page 1: ...ibaPADU 8 16 32 32 R Manual Issue 3 3 Parallel Analog Digital Converter for 8 16 or 32 channels...

Page 2: ...l compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be downloaded on the Internet The...

Page 3: ...Examples for topologies 12 8 Product properties 14 8 1 Properties 14 8 2 Device operating elements and connectors 15 8 2 1 ibaPADU 8 all types 15 8 2 2 ibaPADU 16 ibaPADU 32 ibaPADU 32 R 16 8 2 3 Run...

Page 4: ...ttings in ibaPDA V6 25 10 Technical data 27 10 1 Main data or all Device types 27 10 2 Analog inputs 28 10 3 Binary inputs 29 10 4 Device data 29 10 5 Dimensions drawing ibaPADU 8 30 10 6 Dimensions d...

Page 5: ...egarded to as professional if he she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her spe cialist training knowledge and experience and knowledge...

Page 6: ...rocess and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The n...

Page 7: ...D channels ibaPADU 32 R 19 rack mount device with 32 A 32 D channels and AC 115 V 250 V power supply If no special reference to a device is made in the following text the devices are named as ibaPADU...

Page 8: ...The following safety instructions apply particularly to the devices ibaPADU 16 and ibaPADU 32 32R In order to avoid the risk of electrical shock disconnect the power cord or switch off the power suppl...

Page 9: ...000 ibaFOB io or ibaFOB 4i ibaFOB io S or ibaFOB 4i S ibaFOB 4i X 2i X 2io X or io X not for ibaPADU devices with S N 1000 ibaFOB 4i D 2i D 2io D or io D Laptop computer with ibaCom PCMCIA F copper ba...

Page 10: ...h this action the device should free itself from the DIN rail 6 2 ibaPADU 32 R 6 2 1 Mounting Fix the device with the four front panel screws into the cubicle In case of high me chanical duty accelera...

Page 11: ...s which hold 16 A 16 D channels need two addresses an ibaPADU 32 needs four addresses re spectively Hence you may connect chains of 8 ibaPADU 8 or 4 ibaPADU 16 or 2 ibaPADU 32 with 1 fiber optic link...

Page 12: ...principle of the data pack ages in an ibaFOB telegram Each box contains 8 analog 8 digital signals The device address determines where the data are placed in the te legram Therefore the posi tion of...

Page 13: ...verwriting the data from ibaPADU 16 Figure 3 Mixed chain with ibaPADU 16 and ibaPADU 32 Example 4 Connection to Notebooks via ibaCom PCMCIA F card 4 occupies 4 and 5 1 occupies 1 2 3 and4 2 devices in...

Page 14: ...and 32 is 1000 Hz Sampling rate for ibaPADU 16 32 of version A2 or higher can be set to 800 Hz or 960 Hz this contributes to operation in a 60 Hz mains environment For ibaPADU 8 only in externally syn...

Page 15: ...ddress switch S1 Mode switch S2 Analog inputs 00 07 X1 Digital input status LEDs L4 L11 Digital inputs 00 07 X5 Top view Serial number and E Mail address Bottom view Service interface 9 pin D Sub X12...

Page 16: ...ata for the time period of the interruption 8 2 1 3 Device address setting with Addr switch S1 S1 is used to set the device address 1 8 Each address represents 8 A 8 D chan nels Important note The pos...

Page 17: ...chain on one FO link when using ibaPADU 32 up to 2 devices 8 2 2 3 Device mode setting with mode switch S0 The switch S0 sets the device mode Switch S0 Mode Meaning 0 Standard sampling rate 1000 Hz 1...

Page 18: ...Pin Connector X1 X2 X3 X4 X5 X6 X7 X8 1 AI 00 AI 08 AI 16 AI 24 DI 00 DI 08 DI 16 DI 24 2 AI 00 AI 08 AI 16 AI 24 DI 00 DI 08 DI 16 DI 24 3 AI 01 AI 09 AI 17 AI 25 DI 01 DI 09 DI 17 DI 25 4 AI 01 AI 0...

Page 19: ...te In normal operation mode the V 24 cable must not be connected 8 2 6 Shield connector s for physical earth Proper connection of cable shielding to the device should be ensured The shield con nector...

Page 20: ...k RON device is on and ROFF 50 k Derivatives with inputs of up to 60 V are available also in request see chapter Techni cal data 8 3 3 ibaPADU 8 High Impedance 8 analog inputs with 10 V voltage input...

Page 21: ...n and ROFF 50 k Low pass filter 250 Hz 12 dB Figure 9 Simplified input circuitry of ibaPADU 8 F1 250 Hz 12 dB 8 3 5 ibaPADU 8 I 8 analog inputs with 20 mA RI 50 for current based signals Figure 10 Sim...

Page 22: ...ling rate for all devices is 1 Hz The sampling rate for ibaPADU 8 only may be changed for the devices within one ring topology between 1 0 ms and 9 9 ms in steps of 100 s with ibaLogic and ibaFOB io o...

Page 23: ...on is better than 2 s between any device and any chain This mode is only available with ibaLogic and ibaPADU 8 Only ibaLogic is able to ad dress the ibaFOB output mod ule Special device settings for t...

Page 24: ...baPADU 8 HI F ibaPADU 8 F1 F ibaPADU 8 I F ibaPADU 16 F ibaPADU 32 F ibaPADU 32 R F ibaPADU 8 ICP 1 M ibaPADU 8 M 1 M ibaPADU16 M 1 F M ibaDIG40 1 F M 1 There are separate manuals about these devices...

Page 25: ...an ibaPADU 8 16 or 32 module to the corresponding FOB F PCI data interface Figure 13 I O Manager hardware 9 2 1 2 ibaPDA diagnostics check of settings The correct function of the ibaFOB and or ibaPADU...

Page 26: ...the view provides an overview about the communication parame ters of all FO links A permanent change in Baud rate indicates that no telegram is received This is either due to a missing or faulty fibe...

Page 27: ...z axis all ibaPADU 8 types ibaPadu 32 R 2 g with ad ditional rear holder only EMI test parameters EN 55011 Class A EN 61000 4 6 Class 3 EN 61000 4 3 ENV 50204 Class 3 Operating temperature 32 F to 122...

Page 28: ...22002 R HI 60 10 2 Analog inputs Number 8 8 8 16 32 Resolution 14 bit Dynamics 80 dB 0 Hz to 500 Hz Frequency response Low pass filter 250 Hz 12 dB 8 F1 8 HI F1 Low pass filter 250 Hz 12 dB 16 F1 Inpu...

Page 29: ...ital ground 1 5 kV 10 4 Device data Montage DIN rail snap in mount Table device 19 rack mount Power supply DC 24 V 20 not stabilized AC 115 V 250 V 50 60 Hz Power Current con sumption no load Typ 300...

Page 30: ...Manual ibaPADU 8 16 32 32 R 30 Issue 3 3 10 5 Dimensions drawing ibaPADU 8 Dimensions given in mm Figure 15 Dimensions drawing ibaPADU 8...

Page 31: ...ibaPADU 8 16 32 32 R Manual Issue 3 3 31 10 6 Dimensions drawing ibaPADU 16 Dimensions given in mm Figure 16 Dimensions drawing ibaPADU 16...

Page 32: ...Manual ibaPADU 8 16 32 32 R 32 Issue 3 3 10 7 Dimensions drawing ibaPADU 32 Dimensions given in mm Figure 17 Dimensions drawing ibaPADU 32...

Page 33: ...ibaPADU 8 16 32 32 R Manual Issue 3 3 33 10 8 Dimensions drawing ibaPADU 32 R Dimensions given in mm Figure 18 Dimensions drawing ibaPADU 32 R...

Page 34: ...require support specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E Mail iba iba ag com Co...