ibaMS8xIEPE
Input module for IEPE vibration sensors
Manual
Issue 1.3
Page 1: ...ibaMS8xIEPE Input module for IEPE vibration sensors Manual Issue 1 3 ...
Page 2: ...ed trademark of the Microsoft Corporation Other product and company names mentioned in this manual can be labels or registered trademarks of the corre sponding owners Certification The product is certified according to the European standards and directives This product meets the general safety and health requirements Further international customary standards and directives have been observed Note ...
Page 3: ... Indicator elements 12 7 2 1 Operating status 12 7 2 2 Status of IEPE inputs 13 7 3 Analog inputs 13 7 3 1 Filter 14 7 3 2 Connection diagram pin assignment 15 7 3 3 Error and status signals 16 8 Start up Update 17 8 1 Auto Update 17 8 2 Overall Release Version 17 8 3 Update 17 8 3 1 Update via Web Interface 18 8 3 2 Update via ibaPDA 18 8 4 Module Information Diagnostics 19 8 4 1 Diagnostics 19 8...
Page 4: ...Manual ibaMS8xIEPE 4 Issue 1 3 10 Technical Data 29 10 1 Main data 29 10 2 Analog inputs 29 10 3 Dimensions 31 11 Support and contact 32 ...
Page 5: ...ed in delivery The documentation of the iba modular system comprises the following manuals Central units The manuals of the central units e g ibaPADU S IT 2x16 and ibaPADU S CM con tain the following information Scope of delivery System requirements Description of the device Mounting Demounting Start up Configuration Technical data Accessories Modules The manuals for the single modules contain spe...
Page 6: ...sible consequences and risks on the basis of his her specialist training knowledge and experience and knowledge of the standard regulations 1 2 Notations In this manual the following notations are used Action Notations Menu command Menu Logic diagram Call of menu command Step 1 Step 2 Step 3 Step x Example Select menu Logic diagram Add New logic diagram Keys Key name Example Alt F1 Press keys simu...
Page 7: ...ess and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injury or material damage Note A note specifies special requirements or actions to be observed Important note Note if some speci...
Page 8: ... for IEPE vibration sensors Detection of broken line and short circuit Analog and digital anti aliasing filter Synchronous sampling 4 channels can be configured as 24 V voltage input High pass 1 Hz or 0 1 Hz can be configured Sampling rate 1 kHz1 40 kHz freely adjustable 24 bit resolution Rugged design easy mounting Certification according to CE Fields of application Measurement of mechanical vibr...
Page 9: ...ation of industrial plants Applications with iba products ibaPDA ibaLogic etc The device is only to be applied as shown in the Technical Data 4 2 Special safety instructions Strictly observe the measuring range see Technical Data Never use damaged measuring cables Measuring cables must NOT be attached or detached to from the device under voltage Modules must NOT be attached or detached to from the...
Page 10: ...sue 1 3 5 System Requirements 5 1 Hardware Central unit ibaPADU S IT 2x16 or ibaPADU S CM version 02 12 004 or later Backplane unit e g ibaPADU B4S 5 2 Software ibaPDA version 6 35 0 or later ibaLogic V5 version 5 0 3 or later ...
Page 11: ...ackplane 4 Secure the device with the fixing screws Important Note Always screw tight the device and the modules If you do not screw it tight connecting or disconnecting the connectors for the inputs and outputs might cause damages 6 2 Connecting Note The backplane unit and the device must be connected to a protective conductor 1 Connect all cables 2 If all required cables are connected connect th...
Page 12: ...t view 7 2 Indicator elements The operating status of the device and the status of the analog inputs are shown by colored status LEDs 7 2 1 Operating status LED Status Description L1 green Flashing On Off Device is working Device is not working switched off L2 yellow On Access to the backplane bus L3 white L4 red Off Flashing Normal status no faults Device failure Important note When the LED L4 in...
Page 13: ... shorter than in IEPE 0 1 Hz mode This also applies if the signal was overdriven for a short time The analog inputs can be adjusted to different operating modes per channel The oper ating mode is configured in ibaPDA IEPE input 5 V with 1 Hz high pass filter2 IEPE input 5 V with 0 1 Hz high pass filter 24 V AC input AI 24 V DC input AI 4 inputs are adjusted permanently to IEPE mode The mode of the...
Page 14: ...ed filters are permanently active Figure 2 Filter sections RC high pass The cutoff frequency depends on the mode Mode Cutoff frequency IEPE 0 1 Hz 0 1 Hz IEPE 1 Hz 1 Hz 24 V DC 24 V AC 1 Hz Anti aliasing Butterworth 4th order The cutoff frequency depends on the sampling rate Sampling rate Cutoff frequency 8 kHz 4 kHz 8 kHz 20 Hz Digital anti aliasing filter Parameter Value Group run time 37 f Sett...
Page 15: ...diagram Pin assignment Pin Connection LED Pin Connection LED 1 Analog input 00 L26 1 Analog input 04 L30 2 Analog input 00 2 Analog input 04 3 GND 3 GND 4 Analog input 01 L27 4 Analog input 05 L31 5 Analog input 01 5 Analog input 05 6 GND 50 Ω 6 GND 50 Ω 7 Analog input 02 L28 7 Analog input 06 L32 8 Analog input 02 8 Analog input 06 9 GND 9 GND 10 Analog input 03 L29 10 Analog input 07 L33 11 Anal...
Page 16: ...n line short circuit the signal changes to FALSE 7 3 3 2 Broken line The signal indicates both a broken line and when a IEPE sensor is not connected When the sensor supply voltage exceeds 20 V a broken line will be detected After a delay of 10 seconds the error signal Broken line changes to TRUE When the sensor supply voltage decreases below 20 V again the error state will be reset and the signal ...
Page 17: ...sponding software versions If a module cannot be de tected yet i e it is more recent than the Firmware version of the CPU this module is ignored and outlined in red on the Web interface In this case a new update file has to be installed for the overall release version If you want to get the current update file please contact the iba Support You will also find it on the iba Software Manuals DVD inc...
Page 18: ... Figure 4 Update via Web interface 8 3 2 Update via ibaPDA Open the ibaPDA I O Manager and choose your iba modular system in the tree structure On the Diagnostics tab click on the Write firmware button and choose the padusit2x16_v xx yy zzz iba or paduscm_v xx yy zzz iba update file You start the update by clicking on OK Figure 5 Update via ibaPDA Important note When updating the iba modular syste...
Page 19: ...pen the ibaPDA I O Manager and choose your iba modular system in the tree structure see also the figure above 8 4 2 Web Interface On the module Website general information about the module is displayed You cannot change the values Important note The Web interface is available only with the central unit ibaPADU S IT 2x16 8 4 2 1 info tab The info tab displays general information and technical speci...
Page 20: ...IEPE 20 Issue 1 3 8 4 2 2 notes tab On the notes tab you can enter notes e g for notes on wiring or on recording of changes By clicking on save notes the notes are permanently stored on the device Figure 7 notes tab ...
Page 21: ...8 Automatic detection of the module Note The automatic detection requires a bidirectional FO connection from the ibaPDA com puter to the central unit Other documentation If you want to install the iba modular system at first refer to the manual of the central unit chapter Configuration with ibaPDA 9 1 1 General settings If the module is detected click on the module in the signal tree and the Gener...
Page 22: ...modify the configuration of the modules and signals In this case the configuration is set by the embedded application The following entries can be displayed ibaPDA When ibaPDA is displayed an embedded application has not been started and the configuration can be set by ibaPDA Embedded application When embedded application is displayed the configuration of the modules and signals is set by the embe...
Page 23: ...ibaMS8xIEPE Analog tab Name You can enter a name for the signal and two additional comments click on the icon in the Name field Mode The mode can be selected from a dropdown menu see chapter 7 3 IEPE mode is the fixed setting for channels 0 2 4 and 6 but the filter can be se lected Mode selection for the channels 1 3 5 and 7 ...
Page 24: ...to a physical value Unit You can enter a unit the default setting is g Sensitivity Enter here the sensitivity according to the used IEPE sensor Active Enabling disabling the signal You can show or hide more columns via the context menu click with the right mouse button in the headline 9 1 3 Error and status signals Depending on the operating mode error and status signals can be enabled for each ch...
Page 25: ...broken line only in IEPE mode Status signal indicates whether there is a broken line or a channel is not con nected Channel shorted only in IEPE mode Status signal indicates a short circuit of the channel Channel data valid in IEPE and AI mode Status signal indicates whether the data is valid When AI mode is selected only the signal Channel data valid can be se lected Active Enabling disabling the...
Page 26: ...e signals belonging to this module 9 2 1 Configuring signals The signals can be configured in the I O Configurator of ibaLogic V5 Open the I O Con figurator in the Tools I O Configurator menu When you click on the Update hard ware button then ibaLogic detects the module Figure 12 Inputs ibaMS8xIEPE The analog input channels and the status signals are displayed in the Inputs tab The inputs operatin...
Page 27: ...abled you can see additional input and output signals Figure 13 Additional signals when buffered access is enabled Note You need to apply the Buffered Access by clicking on the Apply button Only then you will see additional signals in the signal tree that can be configured as output or input resources ...
Page 28: ...lugged input module for output module without function 0 Module not initialized 1 Module running 1 Mistake e g module cannot be initialized StatusOut Status information about the plugged output module for input module without function 0 Module not initialized 1 Module running 1 Mistake e g module cannot be initialized Additional input signals for buffered access AI_IEPE_Ch 00 07 _buf Input buffer ...
Page 29: ... 158 F 25 C 70 C Installation position Vertical plugged into backplane bus Humidity class acc to DIN 40040 F no condensation Protection class IP20 Certification Standards EMC IEC 61326 1 FCC part 15 class A Dimensions and weight Dimensions width x height x depth 1 69 in x 8 43 in x 5 83 in 43 mm x 214 mm x 148 mm Weight incl packaging and documentation approx 2 43 lbs 1 1 kg 10 2 Analog inputs Ana...
Page 30: ...V to 24 0 V 5 0 V to 5 0 V at 160 Hz Max input voltage 60 V permanent Input gain IEPE none Sampling rate 1 kHz3 40 kHz freely adjustable Frequency range 0 1 Hz to 20 kHz Error and status signals per channel AI 24 V DC AC IEPE Data valid Data valid broken line shorted Electrical isolation Root root Root housing power supply AC 1 5 kV AC 1 5 kV Connector type inputs 2x 12 pin multi pin connector scr...
Page 31: ...ibaMS8xIEPE Manual Issue 1 3 31 10 3 Dimensions Dimensions in mm Figure 14 Module dimensions ...
Page 32: ... product Contact Headquarters iba AG Koenigswarterstrasse 44 D 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Mailing address iba AG Postbox 1828 D 90708 Fuerth Germany Delivery address iba AG Gebhardtstrasse 10 D 90762 Fuerth Germany Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www iba ag co...