ibaLink-SM-64-io
System Interface for SIMATIC S5 and MMC
Manual
Issue 3.6
Page 1: ...ibaLink SM 64 io System Interface for SIMATIC S5 and MMC Manual Issue 3 6...
Page 2: ...ly so that the full compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be down loaded...
Page 3: ...er Optic Connectors 13 6 1 5 RJ11 Socket 13 6 2 Connectors and Switches on Board 14 6 2 1 S5 Applications Switch Settings on the Board 15 6 2 2 MMC Applications Switch Settings on the Board 16 6 2 3 B...
Page 4: ...s and Offset Assignment 27 8 4 Switch Layout and Application Examples 29 8 5 Multi Processor Mode 155U 30 8 6 The simultaneous bidirectional send and receive mode 135U 33 8 7 Special features of S5 15...
Page 5: ...he she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her specialist train ing knowledge and experience and knowledge of the standard regulations 1...
Page 6: ...trol function The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of inj...
Page 7: ...ses a dedicated memory range on the backplane bus of the S5 or MMC system The data to be measured are written into this memory range by the system where the card is plugged in and are transmitted over...
Page 8: ...blocks on DVD iba Software Manuals P23 k1st s5d for S5 115U 941 944 Cache Mode P23 k2st s5d for S5 115U 945 Cache Mode P23 k3st s5d for S5 135U 928 Cache Mode P23 k4st s5d for S5 150U 924 927 Cache Mo...
Page 9: ...4o X as well as ibaFOB D ibaFOB io ExpressCard also older FOB F ISA cards can be used For measuring on a notebook computer an ibaCom PCMCIA F card type 2 and the corresponding spiral cable are require...
Page 10: ...f the S5 and or MMC rack 4 Take hold of the card by the two grips between thumb and index finger each 5 Slide the card into the appropriate slot of the S5 and or MMC system carefully 6 Before sliding...
Page 11: ...duct Characteristics 6 1 Connectors and Operational Elements on Front Panel Reset button Coding Switch chain offset Status LED busy Sender FO output Receiver FO input RJ11 Notebook computer connector...
Page 12: ...nd integer values Due to the differing data lengths 4 bytes and 2 bytes double data words are transmitted for real values and single data words are transmitted for integers The allocation of the casca...
Page 13: ...etting 9 of the rotary switch at the front panel activates the additional receiver mode of the ibaLink SM 64 io In this transmission mode it is possible to receive and send 64 analog plus 64 binary si...
Page 14: ...side of the board there are three DIL switches which are used to set the format of the data to be transmitted and received on the fiber optical channels Position of the elements System connector X1 DI...
Page 15: ...1 6 A15 0 A15 1 Bit 5 0 Bit 5 1 7 irrelevant Bit 6 0 Bit 6 1 8 irrelevant Bit 7 0 Bit 7 1 Default Setup SW1 OFF 0 ON 1 1 Cache mode S5 Linear mode S5 MMC 2 MMC mode S5 mode 3 8 bit data bus 16 bit dat...
Page 16: ...mode S5 MMC 2 MMC mode S5 mode 3 8 bit data bus 16 bit data bus 4 new telegram 128DW old telegram 32W Addressing Section 1 OFF 0 ON 1 Attention For the BGT 0 BGT01 BGT03 and BGT05 the addresses A22 X...
Page 17: ...ower connector PIN no Row d Row b Row z PIN no Row d Row b Row z 2 NC GND VCC 2 NC GND VCC 4 UBAT PESP CLK 4 NC D8 D12 BHE 6 A12 A0 RESET 6 NC D9 D13 ADB0 8 A13 A1 MRD 8 NC D10 D14 ADB17 10 A14 A2 MWR...
Page 18: ...Board Output Offset 1 1 x 8 Local Value 7 x 8 Values linked in via Cascading Input Middle Board Output Offset 3 3 x 8 Local Values 5 x 8 Values linked in via Cascading Input Left Hand Board Output Off...
Page 19: ...utputs is automatic The transmit mode is indicated by a flashing diode on the front panel Attention The first byte of the dualport ram contains the status of the card when read via the bus backplane S...
Page 20: ...B Byte 64 65 Module Identification of Acquisition Units Level 1 2 ibaLink SM 64 io or ibaPADU K Byte 66 Status of the Acquisition Units Bit0 1 Test Operation Real Transfer Bit1 1 Reception of S5 Reals...
Page 21: ...ing of multiple devices is NOT supported Figure 4 Peer to Peer operation frame to frame connection This operation mode is used to connect two S5 or MMC systems in order to exchange data 64 analog and...
Page 22: ...io card can be used Note For version 6 2 and higher of ibaPDA it is possible to generate digital output signals alarms In order to take advantage of this feature the PC must be equipped with an ibaFO...
Page 23: ...c application the fiber optic input link FO input of the ibaLink SM 64 io card must be connected to the output link of an ibaFOB io or ibaFOB 4o card in the ibaLogic PC This link as well receives 64 a...
Page 24: ...iber optic output or input The devices of the ibaNet 750 family may be used as well for inputs and outputs ibaPDA or ibaLogic systems can be connected too Only daisy chain structures are supported Fig...
Page 25: ...ld be transferred to a data block in a predefined format by the user Integer 115U 135U 155U Function Blocks FB32 and FB33 DW 0 DW 63 64 analog values in KF integer The left hand sections DL are not ut...
Page 26: ...nd Offset start and offset end defines the range real integer or binary from the total num ber of 64 measurement channels KACH D KY cache number 0 255 unused PAFE A BI Configuring error FB31 FB33 Para...
Page 27: ...ibaLink SM 64 io Manual Issue 3 6 27 8 3 1 Data blocks and Offset Assignment 8 3 1 1 Data Block for Real Transfers Figure 8 Data blocks for real transfers...
Page 28: ...Manual ibaLink SM 64 io 28 Issue 3 6 8 3 1 2 Data Block for Integer Transfers Figure 9 Data blocks for integer transfers...
Page 29: ...2 OFF 3 ON 4 OFF 5 OFF 6 OFF 7 OFF 8 OFF Switch OFFSET at 8 irr not relevant These settings allow the programs to be loaded and started in the S5 without modifi cations Programs are contained in the...
Page 30: ...Byte 5 bit 7 channel 47 to bit 0 channel 40 Byte 6 bit 7 channel 55 to bit 0 channel 48 Byte 7 bit 7 channel 63 to bit 0 channel 56 When the channel number is taken into account the measurement entrie...
Page 31: ...e range DW0 DW255 Parameters DBDX D KY Data block NR DL 0 then DB DL 0 then DX DR DB DX No DW D KF The first DW in the block start of block in the DB ANLG D KY DL number of the first channel start DR...
Page 32: ...s are transmitted channel 20 channel 23 ADR A000 One block from address FA000H is utilized BA FX251 Binary values byte by byte DBDX 1 20 The data is contained in DX20 DW 10 The data is in DR10 DR11 an...
Page 33: ...FB42 Integer receive data presets FB43 Integer receive cyclic data transmission Both FBs use one DB The function block contains received analog and binary data as described below and some internal da...
Page 34: ...this is necessary this must be done by the user The analog and digital data is stored similar to the send mode in the following order Integer 135U FB42 and FB43 DW 0 DW63 64 analog values in KF integ...
Page 35: ...res The data block for reals DB30 must be at least 147 DWs long The cards may be inserted in the following slots 3 11 19 107 115 123 131 The package contains an executable example program with two iba...
Page 36: ...rent consumption Typ 350 mA operation switch on 400 mA 5 V Watchdog n a Sample rate 1 ms all channels Max distance of fiber optical cable without repeater 2000 m 6560 ft with appropriate cable Communi...
Page 37: ...e product Contact Headquarters iba AG Koenigswarterstrasse 44 D 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Mailing address iba AG Postbox 1828 D 90708 Fuerth G...